DMTA-20006-01EN, Rev. B, February 2014
Specifications
65
Table 15 Scanner setup chart for smaller pipes
Pipe outside diameter
Tail
setting
Probe-
holder
position
Number of links per side
in.
mm
Half
Male
Female
0.84 to 0.86
21.3 to 21.8
1
Retracted
1
0.86 to 0.89
21.8 to 22.6
1.5
0.89 to 0.91
22.6 to 23.1
2
0.91 to 0.93
23.1 to 23.6
2.5
0.93 to 0.95
23.6 to 24.1
3
0.95 to 0.99
24.1 to 25.1
3.5
0.99 to 1.05
25.1 to 26.7
4
Centered
1.05 to 1.10
26.7 to 27.9
1
Extended
1
1
1.10 to 1.15
27.9 to 29.2
2
1.15 to 1.21
29.2 to 30.7
3
1.21 to 1.28
30.7 to 32.5
4
1.28 to 1.36
32.5 to 34.5
1
Extended
1
2
1.36 to 1.43
34.5 to 36.3
2
1.43 to 1.49
36.3 to 37.8
3
1.49 to 1.56
37.8 to 39.6
4
1.56 to 1.63
39.6 to 41.4
1
Extended
1
1
2
1.63 to 1.70
41.4 to 432
2
1.70 to 1.76
43.2 to 44.7
3
1.76 to 1.88
44.7 to 47.8
4
1.88 to 1.96
47.8 to 49.8
1
Extended
2
3
1.96 to 2.03
49.8 to 51.6
2
2.03 to 2.09
51.6 to 53.1
3
2.09 to 2.16
53.1 to 54.9
4
2.16 to 2.24
54.9 to 56.9
1
Extended
1
2
3
2.24 to 2.30
56.9 to 58.4
2
2.30 to 2.37
58.4 to 60.2
3
2.37 to 2.5
60.2 to 63.5
4
Summary of Contents for COBRA
Page 6: ...DMTA 20006 01EN Rev B February 2014 List of Abbreviations vi...
Page 18: ...DMTA 20006 01EN Rev B February 2014 Important Information Please Read Before Use 12...
Page 56: ...DMTA 20006 01EN Rev B February 2014 Chapter 3 50...
Page 66: ...DMTA 20006 01EN Rev B February 2014 Chapter 4 60...
Page 76: ...DMTA 20006 01EN Rev B February 2014 List of Tables 70...