Olympus CKX41 Brochure & Specs Download Page 1

237.6

195

393.1

515.5

473.7

370.5

364

194.5

237.6

473.2

380.5

486.6

370.5

364

CKX41/CKX31 dimensions

(unit: mm)

• OLYMPUS CORPORATION is ISO14001 certified.
• OLYMPUS CORPORATION is FM553994/ISO9001 certified.

• Illumination devices for microscope have suggested lifetimes.    
  Periodic inspections are required. Please visit our web site for details.

• Specifications and appearances are subject to change without any notice or obligation on the part of  
   the manufacturer.

CKX41/CKX31 are the environmental conscious products according to 
OLYMPUS' own standards.

Main features of OLYMPUS Eco-products are as follows.

• Lead-free and arsenic-free Eco-glass for optics, such as lenses and prisms.
• Exclusion of hexavalent chrome, mercury, lead and cadmium from metal materials and surface 
   treatment of metal.
• Exclusion of lead solders.
• Adoption of cardboard for packing materials without styrene foam for promoting the recycling.
* A definition of exclusion depends on OLYMPUS standard.  Some accessories are inapplicable.

Please visit our web site for further information: http://www.olympus.co.jp/en/eco-products/

Item

CKX41

CKX31

Optical system

UIS2 (Universal Infinity-corrected) optical system

Focus

Vertical nosepiece movement (stage is fixed), 
coaxial coarse and fine focus with tension adjustment mechanism, roller slide mechanism, 
stroke: 7 mm up and 2 mm down from focus position which is 1 mm above the stage, 
stroke per rotation: 36.8 mm (coarse), 0.2 mm (fine)

Revolving nosepiece

Quadruple

Stage

Plain stage

160 mm (L) x 250 mm (W)
Exchangeable insert plate (ø25 mm opening) incorporated

ø35 petri dish holder stage 
incorporated

Mechanical stage

Right-hand low drive coaxial controls, 
stage movement: X=120 mm, Y=78 mm, with three dish/sample holders

Substage

70 (L) X180 (W) mm

Illumination  Light source

6 V, 30 W halogen lamp, lamp socket (U-LS30-3-5), 

system

built-in frosted and heat absorbing filters, detachable illuminator

Filter holder

Insert up to 11 mm thick with ø45 mm filter, detachable

Aperture diaphragm Lever type, range: from minimum ø3 mm to maximum ø44 mm
Slider insertion 

With phase slider pocket and built-in slider position click stop mechanism

Condenser

Detachable ultra-long working distance condenser (N.A. 0.3, W.D. 72 mm)

Contrast slider 

Pre-centered phase contrast: 4X, 10X/20X/40X, empty slot

Centerable phase contrast: 4X, 10X/20X, empty slot (40X optional, pre-centered)

Centerable for Relief Contrast: 10X, 20X, 40X

Observation Binocular tube

U-CBI30-2: inclined 30°, interpupillary distance range: 48-75 mm,

tube

diopter adjustment by helicoid on left sleeve (F.N. 20)
U-BI30-2: inclined 30°, interpupillary distance range: 48-75 mm,
diopter adjustment by helicoid on left sleeve (F.N. 22)

Trinocular tube

U-CTR30-2: inclined 30°, ring dovetail attachment, 
interpupillary distance range: 48-75 mm, tube length 
and diopter adjustment by helicoid on left sleeve
Observation optical path: 50(binocular)/50(video port) (F.N. 20)
U-TR30-2: inclined 30°, ring dovetail attachment, 
interpupillary distance range: 48-75 mm, tube length 
and diopter adjustment by helicoid on left sleeve
Observation optical path: 50(binocular)/50(video port) (F.N. 22)

Tilting binocular 

CKX-TBI: variable inclination angles from 30° to 60°, 

tube

interpupillary distance range: 50-76 mm, 
diopter adjustment by helicoid on right sleeve (F.N. 20)
U-CTBI: variable inclination angles from 30° to 60°, 
interpupillary distance range: 48-75 mm,
diopter adjustment by helicoid on right sleeve (F.N. 18)
U-TBI-3: variable inclination angles from 5° to 35°, circular 
mounting dovetail attachment, interpupillary distance range: 
50-76 mm, diopter adjustment by helicoid on right sleeve. (F.N. 22)

Fluorescent illuminator

Detachable illuminator, 
switchable slide (3-position: B excitation, G excitation, empty slot or U excitation)

FL light source

50 W Hg

FL light shutter

Available

FL field stop

Available

FL cubes

2 cubes (B & G), option U (cubes are not compatible with UIS2. 
Filter and dichroic mirror size are same as UIS2)

Filter

1 filter

Eyepiece

For U-CBI30-2/U-CTR30-2/CKX-TBI: WHB10X/WHB10X-H (F.N. 20)

10X (F.N. 20)

For U-BI30-2/U-TR30-2/U-TBI-3: WHN10x/WHN10x-H/

CROSS WHN10x (F.N. 22)

For U-CTBI: (F.N. 18)

Power supply

Continuous intensity adjustment, 
built-in voltage changeover switch (100/120 V, 220/240 V), frequency 50/60 Hz

CKX41/CKX31 specifications

Fixed binocular tube, inclined
45°, interpupillary distance range:
48-75 mm, diopter adjustment
by helicoid on right sleeve

Printed in Japan M1500E-0910B

Objective

N.A.

W.D.(mm)

Remarks

PLCN4X

0.10

18.5

PLCN10X

0.25

10.6

LUCPLFLN20X

0.45

6.6-7.8

LUCPLFLN40X

0.60

2.7-4

UPLFLN4XPH

0.13

16.4

PHL (for use with IX2-SL)

CPLN10XPH

0.25

10

PHC (for use with IX2-SL)

PLCN10XPH

0.25

10.6

PH1 (for use with IX2-SL)

CPLFLN10XPH

0.3

9.5

PHC (for use with IX2-SL)

LCACHN20XPH

0.40

3.2

PHC (for use with IX2-SL)

LUCPLFLN20XPH

0.45

6.6-7.8

PH1 (for use with IX2-SL)

LCACHN40XPH

0.55

2.2

PH2 (for use with IX2-SL)

LUCPLFLN40XPH

0.6

3.0-4.2

PH2 (for use with IX2-SL)

UPLFLN4XPHP*

2

0.13

16.4

For use with IX2-SLP

CACHN10XPHP*

2

0.25

8.8

For use with IX2-SLP

LCACHN20XPHP*

2

0.40

3.2

For use with IX2-SLP

LCACHN40XPHP*

2

0.55

2.2

For use with IX2-SLP

CPLN10XRC

0.25

9.7

For use with CKX-RC

LCACHN20XRC

0.4

2.8

For use with CKX-RC

LCACHN40XRC

0.55

1.9

For use with CKX-RC

UPLFLN4X

0.13

17

U,B,G

UPLFLN10X2

0.3

10

U,B,G

UPLFLN20X

0.5

2.1

U,B,G

LUCPLFLN20X

0.45

6.6-7.8

U,B,G

LUCPLFLN40X

0.6

2.7 - 4.0

U,B,G

UIS2 objectives *

1

specifications

For brightfield

For phase contrast

For RC

For FL

*

1

Objective lenses are lead free.

*

2

Pre-centering objective

Weight: approx. 8.8 kg   Rated voltage: 85 VA

Weight: approx. 8 kg   Rated voltage: 85 VA

Inverted Microscope

CKX41/CKX31

A New Advance in Routine Inspections

Summary of Contents for CKX41

Page 1: ...ng dovetail attachment interpupillary distance range 48 75 mm tube length and diopter adjustment by helicoid on left sleeve Observation optical path 50 binocular 50 video port F N 20 U TR30 2 inclined 30 ring dovetail attachment interpupillary distance range 48 75 mm tube length and diopter adjustment by helicoid on left sleeve Observation optical path 50 binocular 50 video port F N 22 Tilting bin...

Page 2: ...view Adoption of a UIS2 phase plate optimized for cell culture observation provides higher image contrast The UIS2 phase plate adjusts the contrast according to the thickness of the cell culture producing higher contrast images than those obtainable from conventional systems Low magnification UIS2 video adapters can be used for 0 25X 0 35X 0 5X and 0 63X magnifications enabling clear display of th...

Page 3: ...n takes up minimum laboratory space The slim compact design minimizes the depth of the microscope allowing easy installation right beside the incubator or clean bench Specimens can be taken and immediately set on the microscope stage for quick efficient inspection Easy observation at the clean bench The tilting binocular tube combination makes it unnecessary for researchers to adopt uncomfortable ...

Page 4: ...U FMT F mount adapter U SMAD Sony mount adapter U BMAD Bayonet mount adapter U CMAD3 C mount adapter U TMAD T mount adapter U TV1X 2 Direct image camera port U TV0 25XC C mount camera port with 0 25x lens U TV0 35XC 2 C mount camera port with 0 35x lens U TV0 5XC 3 C mount camera port with0 5x lens U TV0 63XC C mount camera port with0 63x lens CAMERA SYSTEM IX2 SL Phase contrast slider centerable ...

Reviews: