Stove storage and operation must be ensured in a dry area

, as the fireproof colour is not 

moisture resistant. Stove cleaning (except the glass) is performed without the use of water 

cleaning agents, e.g. by vacuuming or brushing. Any modifications of the appliance are 

inadmissible. Only use manufacturer approved spare parts.For tile stoves, the tiles must not be 
cleaned with a wet cloth; use a slightly damp cloth and perform cleaning only if the stove is cold. 

Lubricate the abrasive surfaces of the door hinges and the closing mechanism with 

carbon fat or high-temperature lubricant at regular intervals.

 

 

8. Heating capability 

The heating capability is given in the table below. It means the capability to heat a specific space 

volume to 24°C with regard to the building construction and the stove installation site under 

normal climatic conditions and at the rated stove output. The heating capability may be up to 25 % 

lower at extreme frosts or in badly insulated buildings. The data given in the table are only for your 
guidance. Actual heat loss of the appartment are valid ! 

 

9. Service and installation organizations 

Eventual service or guarantee repairs will by provided by the manufacturer, either directly or via 

the vendor, after receiving a written statement of the reasons for warranty claim. 

 

10. Package and scrapped product disposal 

In accordance with the law and related regulations we recommend the following procedure for 
package and scrapped product disposal.  
 
 

Package:

 

a) use the wooden parts for heating 
b) put the plastic package into a waste container 
c) deliver the screws and holders to the junk yard 
d) put the bag with humidity absorber to separated waste  

 

Scrapped product:

 

a) demount the glass and put it into a separated waste container 
b) put the sealing and fireclay plates to municipal waste 
c) deliver the metal parts to the junk yard 
 

 

11. Installing the hot water distribution (only for the stove with a 

hot water exchanger) 

Summary of Contents for muria

Page 1: ...MANUAL OLYMPIA MURIA...

Page 2: ...f the variety of offered stoves are fitted for smoke flue connection from behind or from above In your own interest please do not put this service manual aside without having read it In terms of safet...

Page 3: ...l data table if the primary air inlet is closed Leave the primary inlet fully open during firing up when the chimney draught is low After the chimney is warmed up the primary inlet can be closed or ha...

Page 4: ...he instructions below 1 The diameter of the chimney for connecting must be at least 18 cm and the chimney must have an effective height of at least 5 m 2 Eventual air condition piping must be at least...

Page 5: ...oke and fly ash from escaping into the room The appliance requires occasional attendance and supervision It can be used in ordinary environment To avoid corrosion during product storage there is an en...

Page 6: ...d the hearth lining will dry slowly The stove varnish will harden which will be accompanied by temporary odour this odour will later entirely disappear This provides that no microcracks varnish damage...

Page 7: ...urn more quickly it means that the appliance has a bigger output but also bigger fuel consumption and vice versa Garbage coal coke and plastic must not be burned in the stove The combustion of such ma...

Page 8: ...e output The heating capability may be up to 25 lower at extreme frosts or in badly insulated buildings The data given in the table are only for your guidance Actual heat loss of the appartment are va...

Page 9: ...ower supply Connect an automatic circulation thermal load min 30 of the exchanger output e g a storage tank or a boiler to the system Connect this circuit manually or by a thermovalve Flush the exchan...