background image

fuel or big draught and air inlet may result in stove overheating and damage. Little draught (less 

than 9Pa) will cause blackening of the glasses and smoke may escape to the room when the stove 

door is open. 

Note:Divided rated heat output, e.g. Pj= 6+4 means - 6 kW will move to the heated room due to 
heat exchange processes, 4 kW will be absorbed by the hot water exchanger. Heat output of all 

connected radiators at required room temperature must correspond with the exchanger output. 

These specifications are available from the manufacturer of the radiators. The exchanger will also 
absorb a part of the free heat loss in burnt gases, which increases the stove efficiency. 

5.2 Removing the ashes

 

Take care to empty the ashpan as soon as it is half full; the cone of ashes may grow close to the 

grate and the grate may be damaged by overheating. The ashes would also reduce the input of 

combustion air. Put the ashes into closed inflammable containers. Wood ashes can be also used as 
fertilizer. Take particular care when removing hot ashes! 

5.3 Recommended fuel

 

Guaranteed fuel, with which rated stove parameters will be achieved, are dry logs with a diameter 

of 5-8 cm and length of 20-30 cm or wood ecobriquettes. Smaller, drier and softer pieces of wood 
will burn more quickly; it means that the appliance has a bigger output, but also bigger fuel 

consumption, and vice versa. Garbage, coal, coke, and plastic must not be burned in the stove. 

The combustion of such matters pollutes the air and damages the stove and the chimney. The 

wood should be stored outside for about 2 years and should be protected from rain. Wood 
dampnes should not exceed 20 %. Loppings and very small pieces of wood should be used only for 

lighting the fire. During heating, the rated stove output given in the technical data table should be 

kept, which means that the given fuel amount will be burned per hour. There is a risk of stove 
damage if the stove is overloaded for a long time. Note: The fuel value is the same for all kinds of 

wood; their specific weight is different. That is why the given fuel consumption is in kg/h. 

 

6. Accessories 

Potholder (glove). For some types a hook for grate manipulation is available. 

 

7. Maintenance and repair 

Your stove is a top quality product and no defects occur during normal operation. Cleaning the 
fireplace stove thoroughly once a year should be sufficient. Always perform cleaning only if the 

stove is cold. We recommend you to ask a chimneyer to do the stove cleaning; he will also check 

and examine the stove. If the door glass is blackened, it can be cleaned with a newspaper or a 
damp cloth soaked in wood ashes, eventually with a special glass cleaner. Do not use cleaning 

agents that may scratch the glass ! 

Summary of Contents for muria

Page 1: ...MANUAL OLYMPIA MURIA...

Page 2: ...f the variety of offered stoves are fitted for smoke flue connection from behind or from above In your own interest please do not put this service manual aside without having read it In terms of safet...

Page 3: ...l data table if the primary air inlet is closed Leave the primary inlet fully open during firing up when the chimney draught is low After the chimney is warmed up the primary inlet can be closed or ha...

Page 4: ...he instructions below 1 The diameter of the chimney for connecting must be at least 18 cm and the chimney must have an effective height of at least 5 m 2 Eventual air condition piping must be at least...

Page 5: ...oke and fly ash from escaping into the room The appliance requires occasional attendance and supervision It can be used in ordinary environment To avoid corrosion during product storage there is an en...

Page 6: ...d the hearth lining will dry slowly The stove varnish will harden which will be accompanied by temporary odour this odour will later entirely disappear This provides that no microcracks varnish damage...

Page 7: ...urn more quickly it means that the appliance has a bigger output but also bigger fuel consumption and vice versa Garbage coal coke and plastic must not be burned in the stove The combustion of such ma...

Page 8: ...e output The heating capability may be up to 25 lower at extreme frosts or in badly insulated buildings The data given in the table are only for your guidance Actual heat loss of the appartment are va...

Page 9: ...ower supply Connect an automatic circulation thermal load min 30 of the exchanger output e g a storage tank or a boiler to the system Connect this circuit manually or by a thermovalve Flush the exchan...