The insert must be installed so that it can always be removed from the surrounding structure if 

necessary. During appliance installation, all local regulations, including regulations related to 

national and European standards, must be complied with. A professional project should be 

elaborated prior to installation. Before the first fire is made, everything must be checked by a 
chimneyer, who will issue a written revision report. Save the report for future reference! 

 

4. Safety regulations 

For seasonal usage and at bad draught or weather conditions it is necessary to pay particular 

attention when putting the appliance into operation. After longer service interruption, checking for 
stoppage in flue ways is necessary prior to making fire. Do not allow children to manipulate with 

the stove. The stove can be operated only by adults ! During heating, operate all handles and 

knobs using tongs, a hook, or a glove (a potholder) – risk of burn injury! During operation, 

combustion air and room ventilation air supply must be ensured, especially when another heating 
device is used at the same time (ca. 6 m3 for burning of 1 kg of fuel)! If the windows and doors 

are well sealed, or if a exhaustion device (a fume hood e.g.) is present, the amount of air may be 

insufficient! Place the combustion, ventilation, and heating air regulating grids, if used, so that they 

cannot get clogged. It is also advisable to ensure sufficient air humidizing in the room.When 
inserting fuel, close the door slowly. This will prevent smoke and fly ash from escaping into the 

room..The appliance requires occasional attendance and supervision. It can be used in ordinary 

environment. To avoid corrosion during product storage there is an enclosed bag with humidity 
absorber. Remove the bag – further see package disposal. For stove installation, safety regulations 

according to must be complied, namely: 

4.1 Safety distances:

 

4.1.1 Minimum distance from combustible or heatsensitive objects. 

These are furniture, wooden linings, textiles, wallpaper, drying clothes, etc. Minimum safety 

distance from the stove is 20 cm on the sides and at the back. The minimum distance is 40 cm for 
stoves without double casing and surface cladding. No easily inflammable object can be placed in 

front of the stove in the distance less than 80 cm. 

4.1.2 Minimum distance between the smoke flue duct and combustible materials. 

The minimum distance between the smoke flue duct and doorframe lining, or likewise located parts 
of building structures made of combustible materials, or pipings, is 40 cm. This also applies to walls 

and especially ceilings with plaster on inflammable base such as lathing, reed lathing, etc. ! If 

these distances cannot be kept, fire hazard must be prevented by means of building technical 

measures, fireproof claddings, heat resistant insulations and firescreens. 4.1.3 Floor protection. 

If the stove is not placed on a floor that is 100 % fireproof, it must be installed on a fireproof 

insulating pad, e.g. sheet metal, ceramics, tempered glass, or stone. The pad must cover the floor: 

a) at least 30 cm in the front, measured from the outside contour of the stove 
b) at least 10 cm at the sides, measured from the edge of the combustion chamber opening. 

Summary of Contents for muria

Page 1: ...MANUAL OLYMPIA MURIA...

Page 2: ...f the variety of offered stoves are fitted for smoke flue connection from behind or from above In your own interest please do not put this service manual aside without having read it In terms of safet...

Page 3: ...l data table if the primary air inlet is closed Leave the primary inlet fully open during firing up when the chimney draught is low After the chimney is warmed up the primary inlet can be closed or ha...

Page 4: ...he instructions below 1 The diameter of the chimney for connecting must be at least 18 cm and the chimney must have an effective height of at least 5 m 2 Eventual air condition piping must be at least...

Page 5: ...oke and fly ash from escaping into the room The appliance requires occasional attendance and supervision It can be used in ordinary environment To avoid corrosion during product storage there is an en...

Page 6: ...d the hearth lining will dry slowly The stove varnish will harden which will be accompanied by temporary odour this odour will later entirely disappear This provides that no microcracks varnish damage...

Page 7: ...urn more quickly it means that the appliance has a bigger output but also bigger fuel consumption and vice versa Garbage coal coke and plastic must not be burned in the stove The combustion of such ma...

Page 8: ...e output The heating capability may be up to 25 lower at extreme frosts or in badly insulated buildings The data given in the table are only for your guidance Actual heat loss of the appartment are va...

Page 9: ...ower supply Connect an automatic circulation thermal load min 30 of the exchanger output e g a storage tank or a boiler to the system Connect this circuit manually or by a thermovalve Flush the exchan...