1. Introduction 

This service manual applies to the fireplace stoves as well as the fireplace inserts (further referred 

to as appliances – for generaltexts). 

We are pleased that you have chosen our product. The appliances are tested in compliance with 
the EN 13 240 and 13 229 standards. They require only very simple attendance and we expect that 

they will serve for a long time to your full satisfaction. The appliances are made as all-metal, or 

they have tile or stone lining and accessories. A part of the production is made using cast iron. 

Some types are, in addition, supplemented with a hot water exchanger for service water used to 
heat the neighbouring rooms. Most types of the variety of offered stoves are fitted for smoke-flue 

connection from behind or from above. 

In your own interest, please do not put this service manual aside without having read it. In terms 

of safety, the user is obliged to be properly informed about the appropriate installation and 

operation of this appliance. This is the purpose of this service manual. High heat output, dust-free 

operation, and minimum escape of polluting matter due to complete combustion are the main 
advantages of your appliance. The appliance is not designed for constant heat operation. 

 

2. Technical description 

The appliances are designed for the heating of rooms and for temporary heating when it is not 

efficient yet to heat by central heating. The fireplace insert is designed for installation in fireplaces 

in various interiors (apartments, recreation objects, restaurants). 
The appliances are made of sheet steel with 2 – 4 mm thickness. Some fireplace inserts are also 

made of cast iron. The surface is protected by fireproof flat varnish. The combustion chamber is 

mostly lined with removable fireclay plates. The bottom of the combustion space is fitted with a 
removable cast iron grate. The door of the combustion chamber is equipped with special heat 

Summary of Contents for muria

Page 1: ...MANUAL OLYMPIA MURIA...

Page 2: ...f the variety of offered stoves are fitted for smoke flue connection from behind or from above In your own interest please do not put this service manual aside without having read it In terms of safet...

Page 3: ...l data table if the primary air inlet is closed Leave the primary inlet fully open during firing up when the chimney draught is low After the chimney is warmed up the primary inlet can be closed or ha...

Page 4: ...he instructions below 1 The diameter of the chimney for connecting must be at least 18 cm and the chimney must have an effective height of at least 5 m 2 Eventual air condition piping must be at least...

Page 5: ...oke and fly ash from escaping into the room The appliance requires occasional attendance and supervision It can be used in ordinary environment To avoid corrosion during product storage there is an en...

Page 6: ...d the hearth lining will dry slowly The stove varnish will harden which will be accompanied by temporary odour this odour will later entirely disappear This provides that no microcracks varnish damage...

Page 7: ...urn more quickly it means that the appliance has a bigger output but also bigger fuel consumption and vice versa Garbage coal coke and plastic must not be burned in the stove The combustion of such ma...

Page 8: ...e output The heating capability may be up to 25 lower at extreme frosts or in badly insulated buildings The data given in the table are only for your guidance Actual heat loss of the appartment are va...

Page 9: ...ower supply Connect an automatic circulation thermal load min 30 of the exchanger output e g a storage tank or a boiler to the system Connect this circuit manually or by a thermovalve Flush the exchan...