olympia electronics BSR-5036 Quick Start Manual Download Page 1

1503600-009-001

1503600.009-001

BSR-5036

Addressable manual call point

24 / 07 / 2003

24 / 07 / 2003

Technical Specifications

Main voltage
Standby consumption
Alarm consumption
Degrees of cover  
Produced in accordance with
Operation temperature range
Humidity
Dimensions
Weight
Guarantee

14-30 V

1 mÁ

1.5 mA (

with activation

 LED)

IP 20

EN 54

o

-20  

60 C

to

Up to 95% relative humidity 

100 x 100 x 60 mm

200 gr

2 years

Description

BSR-5036 is a addressable manual call point which activates the fire detection 

panel. It is essential for it to exist in co-operation with the detectors. At least one 

button has to be placed in every fire detection system, near to the main control 

panel. Pushing the clear plastic cover, the button activates the alarm system. The 
clear plastic cover does not brake but can be reset to it

s original position with the 

special plastic key which is included in the package. With this way you can test a 
specific button as well maintenance  the  fire  detection  panel.
It is mounted in a clearly  visible  spot, near at exit or ladder and at a height of 1,5 
metres.

    

A red coloured  LED that blinks periodically in standby detection mode, is a power 

indication LED and indicator for the good operation of the device. When a button 

issues an alarm the LED lights. When we sillence  the sirens the LED remains lit to 

show us the detector that issued the alarm.

The LED goes off when we RESET the panel. 

Each button has an address with which it is recognized from the panel. 
It

s forbidden for two devices with same  addresses to be connect to the same loop.

The back page contains all the available address settings which are done using the 

dipswitch.
The panel references the buttons with the name  

‘’

CALL POINTS 

‘’

+L -L +L -L

A

P

1
2
3
4
5
6
7
8

O

N

Indicator LED

.

Blinks periodically in standby detection mode. 

The LED light when a button issue an alarm.

The LED goes off when we RESET the panel

   Select the signal that the button  sends to the panel. 

In position (Á)

 

the button sends an alarm signal.

In position (Ñ) the button sends a prealarm signal .

(We have to also programm the pane

l

)

      Address selection dipswitches .

Åach device has its own address.

Terminal block for connecting to the loop.

+

L

-L

+

L

-L

A

P

1

2

3

4

5

6

7

8

ON

+

L

-L

+

L

-L

A

P

1

2

3

4

5

6

7

8

ON

Loop

Loop

Loop

Loop

IN

IN

O

U

T

OU

T

R

IN

IN

O

U

T

OU

T

R

IN

IN

O

U

T

OU

T

R

IN

IN

O

U

T

OU

T

R

IN

IN

O

U

T

OU

T

R

Reviews: