ELECTRICAL WIRING
Install electrical wiring in accordance with requirements
of authority having jurisdiction, or in absence of such
requirements, Canadian Electrical Code, Part I, CSA C22.1,
Electrical Code.
A separate electrical circuit should be run from the entry
box with a fused disconnect switch in this circuit. See
wiring diagram in
Figure 19, Page 16
.
Wiring for zone valve installations are furnished with zone
valve packages.
Thermostat Installation
1.
Thermostat should be installed on an inside wall about
four feet above the
fl
oor.
2.
NEVER
install a thermostat on an outside wall.
3.
Do not install a thermostat where it will be affected
by drafts, hot or cold pipes, sunlight, lighting
fi
xtures,
television,
fi
replaces, or chimneys.
4.
Check thermostat operation by raising and lowering
thermostat as required to start and stop the burner.
5.
Instructions for the
fi
nal adjustment of the thermostat
are packaged with the thermostat (adjusting heating
anticipator, calibration, etc.).
WARNING
Electrical shock hazard. Turn OFF electrical power
supply at service panel before making electrical
connections. Failure to do so could result in death
or serious injury.
!