XZAC4219-03 Service
Manual
4-27
It is necessary to measure the width of the form to permit faster management of the magnetic stripe of the
passbooks. Selecting, via set-up, the "STRIPE HANDLING: FAST" item, the value read with the form
measurement procedure will be used to determine the position of the magnetic stripe and for positioning of the
stripe above the magnetic head (without having to make several measurements of passbook width). This
considerably reduces passbook management time. If this type of management is to function correctly, the
same passbooks as measured must be used.
To carry out this calibration, proceed as follows:
1.
Switch on the printer with the cover open holding down the three console buttons.
2.
Wait for the acoustic signal that indicates access to the calibration and adjustment procedure.
3.
Press the Local button and wait for the end of the machine reset procedure.
4.
Insert an A4 sheet in the front slot and press Station 1. The sheet will be introduced and
ejected automatically.
5.
If necessary, repeat point 5.
6.
Press the “Local” button to permanently save the value of the form width measured and to
move automatically to the next calibration.