DISPLAY MESSAGES
The following table lists the messages of state, warning and error that can be visualized on the display of the
console, when the printer is equipped with alphanumeric display.
Power on messages
MESSAGE
TIME OUT
DESCRIPTION
Olivetti
PR2 PLUS
No timeout
Startup message
Start Up
COVER OPEN
No timeout
Startup condition. Means please close cover for continue.
RS232 Error
1 second
Serial channel (parity, framing, overrun).
ERROR
RFID Time Out
10 seconds
RFID module.
ERROR
SBI Time Out
10 seconds
SBI (serial BUS vs MICR Option)
•
Replace the MICR board. See the section
“Horizontal
magnetic/MICR disassembly/reassembly” on page 7 - 28
•
Replace the MICR head.
See the section
“Horizontal magnetic/MICR printhead assy
disassembly/reassembly” on page 7 - 30
.
WARNING
Setup Software
No timeout
Inconsistency in printer configuration data (programming values)
saved in the dedicated Flash EPROM area. The printer forces the
default values for the firmware release.
•
Press any key on the console, when appropriate, to display
the next anomaly.
•
Check if the default values forced by the printer are the correct
ones by printing the configuration data. See the section
“Activating and deactivating the print test” on page 2 - 10
•
Proceed with initialisation of the printer.
WARNING
Setup Hardware
No timeout
Inconsistency of calibration values (photosensors, alignments etc).
All the calibration values are initialised with their default values.
•
Press any key on the console to display the next anomaly,
when necessary.
•
Perform all the printer calibrations. See the section
“PROGRAMMING AND CALIBRATION” on page 4 - 1
•
Replace the motherboard. See the section
Disassembling/
reassembling the motherboard (printers with scanner)
or
Disassembling/reassembling the motherboard (printers with
serial number 8.xxx.xxx and 1.xxx.xxx)
.
WARNING
Mainten. Data
No timeout
Memory Maintenance data area corrupted.
Impossible to recover valid maintenance data from the dedicated
Flash EPROM area. The maintenance data will be reinitialised
with the value «0».
ERROR
Characters Gen.
No timeout
Character generator missing or corrupt
Proceed with forced loading of the firmware and of the character
generator.
Summary of Contents for PR2 PLUS
Page 1: ...Printer PR2 PLUS Code XZAC4219 05 SERVICE MANUAL...
Page 4: ...IV Service Manual XZAC4219 05 Page left intentionally blank...
Page 10: ...Index x Page left intentionally blank...
Page 83: ...XZAC4219 05 Service Manual 4 29 Figure 4 6 Scanner calibration parameters...
Page 84: ...4 30 Service Manual XZAC4219 05 Page left intentionally blank...
Page 120: ...6 16 Service Manual XZAC4219 05 Page left intentionally blank...
Page 127: ...XZAC4219 05 Service Manual 7 7 Figure 7 8 Removing the mechanical assembly unit 2 3...
Page 158: ...7 38 Service Manual XZAC4219 05 Page left intentionally blank...
Page 170: ...A 8 Service Manual XZA4219 05 Page left intentionally blank...
Page 172: ......