XZAC4219-05
Service Manual
5-5
O
-
X
-
-
Photosensor test
failed
See the section
“CALIBRATING
THE PHOTOSENSORS” on page 4
- 18
for an indication of the defective
photosensor.
O
-
X
-
X
Magnetic reset
Replace the horizontal magnetic or
MICR interface card. See the
section
“Horizontal magnetic/MICR
disassembly/reassembly” on page 7
- 28.
O
-
X
X
-
AFE scanner
error
•
Perform calibration of the
scanner. See the section
“Calibrating the scanner” on
page 4 - 28.
•
Replace the CIS. See the
sections:
“CIS assy (upper
scanner) disassembly/
reassembly” on page 7 - 33
and
“CIS assy (lower scanner)
disassembly/reassembly” on
page 7 - 34.
O
O
X
X
X
Memory
Maintenance -
On the display (if
present) appears
the message
«
WARNING
Maintenance
data
».
Impossible to
recover valid
maintenance
data from the
dedicated Flash
EPROM area.
The maintenance
data will be
reinitialised with
the value «0».
•
Press any key on the console to
display the next anomaly, when
necessary.
•
Proceed with initialisation of the
printer.
O
X
-
-
-
Service motor
See the section
“Faults with
document handling” on page 5 - 19.
O
X
-
-
X
Paper jammed
on insertion
photosensors
or photosensors
dirty
See the section
“PROCEDURE
FOR CLEANING / REPLACING
THE PHOTOSENSORS” on page 6
- 2.
Console LED
Anomalies
Possible solution
ON
Ready
Station1
Local
Station 2
Summary of Contents for PR2 PLUS
Page 1: ...Printer PR2 PLUS Code XZAC4219 05 SERVICE MANUAL...
Page 4: ...IV Service Manual XZAC4219 05 Page left intentionally blank...
Page 10: ...Index x Page left intentionally blank...
Page 83: ...XZAC4219 05 Service Manual 4 29 Figure 4 6 Scanner calibration parameters...
Page 84: ...4 30 Service Manual XZAC4219 05 Page left intentionally blank...
Page 120: ...6 16 Service Manual XZAC4219 05 Page left intentionally blank...
Page 127: ...XZAC4219 05 Service Manual 7 7 Figure 7 8 Removing the mechanical assembly unit 2 3...
Page 158: ...7 38 Service Manual XZAC4219 05 Page left intentionally blank...
Page 170: ...A 8 Service Manual XZA4219 05 Page left intentionally blank...
Page 172: ......