4-4
Service Manual
XZAC4219-05
14.
To save the new values you have configured for the
parameters, press the
STATION2
key to pass from the value
«NO» to the value «Y».
15.
The value «Y» is printed to confirm that the new configuration
values are saved.
16.
Press the
STATION1
key to save the new configuration.
NOTE:
if you do not want to save the new configuration, press the
STATION1
key when the value «SAVE
PARAMETERS: NO» is printed.
Procedure to save the value of a single parameter
The procedure illustrated above allows you to scroll through all the parameters of the menu selected, changing the
values of the parameters as required.
The procedure described below on the other hand allows you to change the value of a single parameter, exiting
immediately from the menu at the end without having to scroll through all the other parameters.
NOTE:
in this case also, let's imagine that we only want to change the value of the «INTERFACE»
parameter in the Configuration menu «CONFIG.».
1
Proceeding as indicated in the previous section, print the
setting of the fifth parameter «INTERFACE» that is to be
changed.
2.
This is the parameter that, in our example, we want to
change. Press the
STATION2
key to pass to the next value
for the parameter.
3.
The new value for the parameter is printed. For the
connection interface, 6 values are possible: «USB»,
«COM1-USB», «USB-PAR», «PARALLEL»,
«DUAL-PAR» and «SERIAL1».
4.
When you reach the value for the parameter desired, press
the
LOCAL
key to confirm the new value and exit from the
menu.
PRINT MODE:
STANDARD
BIM MODE:
MONO
PNS SELECTIONS:
N
SAVE PARAMETERS:
NO Y
SPECIAL FORMS:
N
MENU:
CONFIG.
DRAFT SPEED:
NORMAL
LQ TYPE:
LQ2
PAPER WIDTH:
FIRST LINE
BUZZER:
Y
INTERFACE:
USB
DRAFT SPEED:
NORMAL
LQ TYPE:
LQ2
PAPER WIDTH:
FIRST LINE
BUZZER:
Y
INTERFACE:
USB COM1-USB PARALLEL DUAL-PAR
SERIAL1
LQ TYPE:
LQ2
PAPER WIDTH:
FIRST LINE
BUZZER:
Y
INTERFACE:
USB COM1-USB PARALLEL
SAVE PARAMETERS:
Y
Summary of Contents for PR2 PLUS
Page 1: ...Printer PR2 PLUS Code XZAC4219 05 SERVICE MANUAL...
Page 4: ...IV Service Manual XZAC4219 05 Page left intentionally blank...
Page 10: ...Index x Page left intentionally blank...
Page 83: ...XZAC4219 05 Service Manual 4 29 Figure 4 6 Scanner calibration parameters...
Page 84: ...4 30 Service Manual XZAC4219 05 Page left intentionally blank...
Page 120: ...6 16 Service Manual XZAC4219 05 Page left intentionally blank...
Page 127: ...XZAC4219 05 Service Manual 7 7 Figure 7 8 Removing the mechanical assembly unit 2 3...
Page 158: ...7 38 Service Manual XZAC4219 05 Page left intentionally blank...
Page 170: ...A 8 Service Manual XZA4219 05 Page left intentionally blank...
Page 172: ......