XZAC4219-05
Service Manual
7-25
7.
Back off the two screws
(1)
of the Centronics interface connector and extract the motherboard from the
baseplate of the printer.
Figure 7 - 33
Parallel interface connection screws
NOTE:
when replacing the board, update the firmware with the latest release, configure the parameters
(see the section
“CONFIGURING THE OPERATION PARAMETERS” on page 4 - 1
) and calibrate
the photosensors (see the section
“CALIBRATING THE PHOTOSENSORS” on page 4 - 18
).
WARNING:
when reassembling the motherboard, tighten the screws of the earth connections for
both the board and the power unit, ensuring a perfect grounding.