7-6
Service Manual
XZAC4219-05
Mechanical assy disassembly/reassembly
1.
Disassembling the casing. See the section
“Casing disassembly/reassembly” on page 7 - 4
.
2.
On both sides, back off the lock-screws
(1)
of the tabs that fasten the front rubber pads so that these can be
removed from their housing.
Figure 7 - 6
Disassembling the mechanical assy
3.
From the front, lift the entire mechanism from the base plate and rotate it partially so as to access the
connectors of the motherboard.
4.
Disconnect all the connection cables of the mechanism to the motherboard, except for the motherboard - power
supply unit connection cable.
Figure 7 - 7
Disconnecting the cables
5.
Loosen the lock-screws
(2)
of the tabs that fasten the rear rubber pads so that these can be removed from their
housing.
6.
Back off the screw
(3)
that fastens the ground cables.
7.
Lift the mechanical assy and separate it from the base plate.
1
Printers with serial number 8.xxx.xxx
Printers with serial number 1.xxx.xxx
Summary of Contents for PR2 PLUS
Page 1: ...Printer PR2 PLUS Code XZAC4219 05 SERVICE MANUAL...
Page 4: ...IV Service Manual XZAC4219 05 Page left intentionally blank...
Page 10: ...Index x Page left intentionally blank...
Page 83: ...XZAC4219 05 Service Manual 4 29 Figure 4 6 Scanner calibration parameters...
Page 84: ...4 30 Service Manual XZAC4219 05 Page left intentionally blank...
Page 120: ...6 16 Service Manual XZAC4219 05 Page left intentionally blank...
Page 127: ...XZAC4219 05 Service Manual 7 7 Figure 7 8 Removing the mechanical assembly unit 2 3...
Page 158: ...7 38 Service Manual XZAC4219 05 Page left intentionally blank...
Page 170: ...A 8 Service Manual XZA4219 05 Page left intentionally blank...
Page 172: ......