Field Service Ver. 1.0 Feb. 2007
7. Mechanical adjustment
15
PK-512/513
Adjustment / Setting
7.
Mechanical adjustment
7.1
Punch hole deviation correction
1.
Insert a piece of paper [1] into the
finisher’s interlock to turn it ON.
2.
Turn ON the Main and Sub power
switches of the machine, and make
sample copies for both the single-
side and double-side with any tray in
Punch mode.
NOTE
• ADF cannot be used to produce the
samples.
3.
Fold the output paper in half and
check whether the punch holes are
aligned. If the punch holes are mis-
aligned, make the following adjust-
ment.
4.
Remove three screws [1] and
remove the punch kit cover [2].
5.
Loosen four screws [1] and move the
punch kit to the left or right by the
amount that needs to be corrected
referring to the mark [2].
• Wider at the rear [3]: Move the punch
kit to the left.
• Wider at the front [4]: Move the punch
kit to the right.
A04EF3C505DA
[1]
A04EF3C503DA
[1]
[2]
[1]
A04EF3C504DA
[1]
[1]
[2]
[3]
[4]
Y108421-6 Service Manual