Functions
Changes the default PDL for each brand. PDLs that are disabled in this
menu will not be displayed at EMULATE of User Menu or OP MENU of
Admin Menu. (No specific to PCL XL is provided; thus, when DISABLE
is set, there is not visual change.)
When print data in the PDL language set to DISABLE is received, the
printer will desplay INVALID DATA and discard received data.
PS3 EMU will be displayed only when PSE is installed.
For this model, PCL cannot be set to DISABLE. (ENABLE must be set
to make it always usable. Even if set to DISABLE, received data will
be processed.)
Displayed only if an RS232C is installed.
Loop Test runs Serial I/F function test without connecting the host PC.
The printer alone sends/receives “00”FFH” data.
Loop Test requires attachment of a Loop connector (pin2: TD and pin3:
RD are shorted) prior to execution.
A Loop count is displayed real-time on LCD, and if an error occurs, an
error message will be displayed.
This mode can be ended only by turning the power off. Following this
operation, the power is shut down; thus, the printer cannot go back in
Operation Mode or other Maintenance Mode.
PRINTING Rolling ASCII Continuous Print Continuously prints Rolling
ASCII patterns for various types continuos testing on the maker side.
(Noise test, engine test).
This mode can be ended by pressing the “ONLINE” SW.Following this
operation, the power turns off, thus, the printer cannot return to either
operation mode or any of other maintenance modes.
Set the dot shift for the horizontal direction when printing from Tray 1.
This area will not be initialized by the EEPROM reset operation.
Set the dot shift for the horizontal direction when printing from Tray 2.
This item is displayed even when Tray 2 is not set. This area will not be
initialized by the EEPROM reset operation. (At first, it is initialized by
default.)
Set the dot shift for the horizontal direction when printing from MPF.
This item is displayed even when MPF is not set. This area will not be
initialized by the EEPROM reset operation. (At first, it is initialized by
default.)
Set the dot shift for the horizontal direction when printing from the
manual slot.
This area will not be initialized by the EEPROM reset operation. (At first,
it is initialized by default.)
Details depend on NETWORK.
Enters Engine Maintenance Menu.
Item
PCL
IBM PPR
EPSONFX
PS3 EMU
ESC/P
PCL XL
RS232C
CONT PRT
TRAY1
TRAY2
MPF
MANUAL
Value
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
EXECUTE
EXECUTE
-4.0 mm
˜
-0.5 mm
0 mm
+0.5 mm
˜
+3.5 mm
-4.0 mm
˜
-0.5 mm
0 mm
+0.5 mm
˜
+3.5 mm
-4.0 mm
˜
-0.5 mm
0 mm
+0.5 mm
˜
+3.5 mm
-4.0 mm
˜
-0.5 mm
0 mm
+0.5mm
˜
+3.5 mm
Category
EMULATE
LOOPTEST
COMT
PRT
DOTSHIFT
NETWORK
ENG DIAG
Detailed descriptions of these functions are provided in Appendix E,
DIAGNOSTICS TEST
.
Summary of Contents for PG L22 Special
Page 1: ...PG L22 Special Printer SERVICE MANUAL Code Y103920 3...
Page 18: ...Y103920 3 Service Manual 18 Upper cover unit Figure 2 2 Upper cover...
Page 136: ...Y103920 3 Service Manual 136 6 PARTS LIST Figure 6 1 Multi Purpose Feeder 9 5 7 6 4 1 2 3 8...
Page 137: ...Y103920 3 Service Manual 137 Table 6 1 Multi Purpose Feeder...
Page 151: ...Y103920 3 Service Manual 151 Table 6 1 High Capacity Paper Feeder...
Page 164: ......
Page 165: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 12 2004 1ST EDITION 165 Y103920 3...