Field Service Ver. 7.0 Jan. 2009
7. SERVICE MODE
8
7
FK-502/Network Fax
ADJUSTMENT
/ SETTING
5.
Select the item and change parameter setting by pressing the [ + ] key / [ - ] key.
6.
Press the [END] key to return Service Mode screen.
15LAF3E023DA
Parameter
Set Value
Factory-shipped
default setting
Reference
V34:1/2
Rx Max. Bit Speed
33600 to 2400 [bps]
(in steps of 2400)
33600 [bps]
Tx Max. Bit Speed
33600 to 2400 [bps]
(in steps of 2400)
33600 [bps]
Control CH Speed
2400, 1200 [bps]
1200 [bps]
Yes
Max. SYMB Speed
3429, 3200, 3000, 2800,
2400 [SYMB]
3429 [SYMB]
Yes
V34:2/2
SYMB Select
Criterion (S/N)
-6 to +6 [dB] (in steps of 1 dB)
0 [dB]
Yes
Main CH Speed
Selection Standard
-8 to +7 [dB] (in steps of 1 dB)
0 [dB]
Yes
SYMB Select
Criterion (Distortion)
-6 to +6 [dB] (in steps of 1 dB)
0 [dB]
Yes
V17 Send
Max
Speed
TX Max. Speed
V17-14400 to V27-2400 [bps]
V17-14400 [bps]
RX Max. Speed
V17-14400 to V27-4800 [bps]
V17-14400 [bps]
TxATT
PIX TxATT
The setting value are different depending on the
country.
Yes
TONE/Procedure
Signal TxATT
Yes
CED/ANSam TxATT
Yes
DTMF TxATT
Level
CD/SED ON Level
-48 to -33 [dBm]
(in steps of 5 dB)
-48 [dBm]
Yes
DTMF H-L Level Dif-
ference
1.0 to 4.0 [dB]
(in steps of 0.5 dB)
2.0 [dB]
Cable
EQL
TX
0 - 12 [dB] (in steps of 4 dB)
0 [dB]
Yes
RX
0 - 12 [dB] (in steps of 4 dB)
0 [dB]
Yes
Y104784-2 Service Manual
Summary of Contents for FK-502
Page 1: ...FK 502 Option Printer SERVICE MANUAL Code Y104784 2 ...
Page 24: ...Y104784 2 Service Manual 17 This page is intentionally left blank ...
Page 68: ...Y104784 2 Service Manual 61 This page is intentionally left blank ...
Page 111: ...104 Service Manual Y104784 2 This page is intentionally left blank ...