2. COMMUNICATION CONTROL
Field Service Ver. 7.0 Jan. 2009
4
4
FK-502/Network Fax
OUTLINE
G. Re-synchronization procedure / Startup procedure
• A procedure required to switch control channel and main channel in the half-duplex pro-
cedure
• A procedure which includes another modulation parameter exchanging is especially
called the startup procedure. (used for changing the communication speed)
(1) Startup procedure
• Control channel startup procedure: See the 3-3 figure. (By exchanging MPh, the commu-
nication speed is changed.)
• “Control channel re-synchronization procedure” is not used.
(2) Re-synchronization procedure
• Control channel re-synchronization See signals related to control channels in 3-3 for sig-
nal names and change method.
Main channel re-synchronization procedure and Turn-off
• The receiving modem re-synchronizes the main channel by using the PP signal. After
B1, starts receiving Primary Data.
• The transmitting modem sends the scrambled 1’s for 35ms after Primary Data transmis-
sion has been completed.
• Both modems move to the control channel re-synchronization procedure or the control
channel startup procedure.
S
:Signal which sends alternately 0 point and a point which rotated 0 point coun-
terclockwise by 90 degrees
:Signal which sends alternately a point which rotated 0 point counterclockwise
by 180 degrees and a point which rotated 0 point counterclockwise by 270
degrees
PP
:Special for adjusting an equalizer
B1
:High-speed signal of one frame length which is sent at the end of a series of
startup sequence in the selected modulation parameter.
Transmitting modem
Receiving modem
Main channel data
Sh
ALT
8T
16T and more
70
±
5ms
E
control channel data
ALT
E
control channel data
24T
Between 16T and 120T
120T or less
Sh
Sh
Sh
24T
8T
Transmitting modem
Receiving modem
Control channel data
S
PP
16T
Turn-off
35ms
70 ± 5ms
B1
Scrambled 1’s
S
128T
Main channel
70 ± 5ms
Control channel data
To Control channel re-synchronization / Control channel startup procedure
Data
Service Manual Y104784-2
Summary of Contents for FK-502
Page 1: ...FK 502 Option Printer SERVICE MANUAL Code Y104784 2 ...
Page 24: ...Y104784 2 Service Manual 17 This page is intentionally left blank ...
Page 68: ...Y104784 2 Service Manual 61 This page is intentionally left blank ...
Page 111: ...104 Service Manual Y104784 2 This page is intentionally left blank ...