2H0/2HZ
1-3-68
U411
Adjusting the scanner automatically
Description
Uses a specified original and automatically adjusts the following items in the scanner and the DP scanning
sections.
Purpose
To perform automatic adjustment of various items in the scanner and the DP scanning sections.
To adjust scanner automatically when initializing the machine using the maintenance item U020 or U022.
Method
1. Press the start key.
2. Select the item. The screen for executing is displayed.
Method: SCANNER
1. Select [SCANNER].
2. Enter the target values which are shown on the specified original executing mainte
nance
item U425.
3. Set a specified original on the platen.
4. Select the item.
5. Press the start key. Auto adjustment starts.
When automatic adjustment has normally completed, [RESULT OK 00] is displayed. If a problem occurs
during auto adjustment, [ERROR XX] (XX is replaced by an error code) is displayed and operation
stops. Should this happen, determine the details of the problem and either repeat the procedure from
the beginning, or adjust the remaining items manually by running the corresponding maintenance items.
6. To return to the screen for selecting an item, press the stop key.
Maintenance
item No.
Description
Display Description
SCANNER Automatic adjustment in the scanner section
DP Automatic adjustment in the DP scanning section
Display
Description
ALL
Automatic adjustment using the platen for: original size magnification/leading
edge timing/center line, input gamma, chromatic aberration filter, MTF filter,
matrix, input gamma in monochrome mode and MTF filter in monochrome
mode
INPUT
Automatic adjustment using the platen for: original size magnification/leading
edge timing/center line
GAMMA
Automatic adjustment using the platen for: input gamma
C.A.
Automatic adjustment using the platen for: chromatic aberration filter
MTF
Automatic adjustment using the platen for: MTF filter
MATRIX
Automatic adjustment using the platen for: matrix
MONO GAMMA
Automatic adjustment using the platen for: input gamma in monochrome
mode
MONO MTF
Automatic adjustment using the platen for: MTF filter in monochrome mode
Service Manual
Y108620-5
Summary of Contents for d-Copia 2500MF
Page 1: ...d Copia 2500MF d Copia 3000MF Digital Copier SERVICE MANUAL Code Y108620 5...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 14: ...2H0 2HZ This page is intentionally left blank...
Page 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank Service Manual Y108620 5...
Page 258: ...2H0 2HZ 2 1 20 This page is intentionally left blank Service Manual Y108620 5...
Page 296: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2007 1ST EDITION 296 Y108620 5...