2NC/2NF/2NG/2NN/3P7/3P8/3P9
1-4-31
6230
Broken fuser thermistor 1
wire (Edge)
Input from fuser thermistor 1
is 1012 or more (A/D value)
continuously for 5 s.
Input from fuser thermistor 1
is1012 (A/D value) or more
whenthe temperature at the
fuser thermistor 2 is 70°C/
158°F or more.
Fuser unit
1. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Fuser unit and main/engine PWB
(YC14)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. Replace the Fuser unit and execute
U167 counter clear (see page 1-3-56).
Main/Engine PWB
1. Check the main/engine software and
upgrade to the latest, if necessary.
2. Replace the main/engine PWB (see
page 2-2-11).
6400
Zero-cross signal error
While fuser heater ON/OFF
control is performed, the zero-
cross signal is not input within
3 s.
Fuser unit
1. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Power source PWB (CN2) and main/
engine PWB (YC14)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. Replace the power source PWB.
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for d-Copia 1801MF Plus
Page 6: ...This page is intentionally left blank...
Page 12: ...This page is intentionally left blank...
Page 18: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 This page is intentionally left blank...
Page 54: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 1 2 24 This page is intentionally left blank...
Page 172: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 1 3 118 This page is intentionally left blank...
Page 282: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 1 4 110 This page is intentionally left blank...
Page 440: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 2 3 4 This page is intentionally left blank...
Page 449: ...Installation Guide DP 480 Document processor Installation Guide...
Page 452: ...2 3 4 5 6 A...
Page 453: ...3 7 8 9 B C C...
Page 454: ...4 10...
Page 467: ...PF 480 300 sheet Paper feeder Installation Guide...
Page 470: ...2 5 6 4 3 B M3x8 B M3x8 B M3x8 B M3x8 1 2...
Page 471: ...3 9 10 8 7 1 2...
Page 472: ...4 13 12 11 1 2 C...
Page 473: ...5 15 14 E D D E D D E D D E D D...
Page 476: ...DU 480 duplex unit Installation Guide...
Page 478: ...1 2 3 1 A B M3x8...
Page 479: ...2 6 7 5 4 A A B M3x8...
Page 483: ...IB 33 Network interface kit Installation Guide...
Page 484: ...2 3 1 IB 33 2013 7 303PB56710 01 A B...
Page 485: ...6 7 5 4 2013 7 303PB56710 01 B YC2007 A...
Page 486: ...FAX System X Installation Guide...
Page 489: ...2 5 4 3 2 B M3x8 A YC 2003...
Page 490: ...3 8 9 7 6 C G G 8 9 7 6 C...
Page 491: ...4 11 10 12 13 D D E...