1-2-1 Installation environment
1-2 Installation
1. Temperature: 10 to 32.5°C/50 to 90.5°F
2. Humidity: 15 to 80% RH
3. Power supply: 120 V AC, 8.5 A
220 - 240 V AC, 4.5 A
4. Power source frequency: 50 Hz ±2%/60 Hz ±2%
5. Installation location
Avoid direct sunlight or bright lighting. Ensure that the photoconductor will not be exposed to direct sun-
light or other strong light when removing paper jams.
Avoid locations subject to high temperature and high humidity or low temperature and low humidity; an
abrupt change in the environmental temperature; and cool or hot, direct air.
Avoid places subject to dust and vibrations.
Choose a surface capable of supporting the weight of the machine.
Place the machine on a level surface (maximum allowance inclination: 1 ).
Avoid air-borne substances that may adversely affect the machine or degrade the photoconductor, such
as mercury, acidic of alkaline vapors, inorganic gasses, NOx, SOx gases and chlorine-based organic sol-
vents.
Select a well-ventilated location.
6. Allow sufficient access for proper operation and maintenance of the machine.
400 mm
15 3/4"
300 mm
11 13/16"
300 mm
11 13/16"
300 mm
11 13/16"
600 mm
23 5/8"
Figure 1-2-1
1-2-1
Summary of Contents for d-COLOR P2026
Page 1: ...d Color P2021 d Color P2026 SERVICE MANUAL...
Page 3: ...This page is intentionally left blank...
Page 9: ...This page is intentionally left blank...
Page 13: ...This page is intentionally left blank...
Page 33: ...This page is intentionally left blank 1 2 14...
Page 54: ...This page is intentionally left blank 1 3 21...
Page 95: ...This page is intentionally left blank 1 4 41...
Page 141: ...4 Remove the paper conveying unit 1 Paper conveying unit 2 2 Figure 1 5 71 1 5 47...