5.3.2 Normal self-diagnostic mode (Level 1)
The menus of the normal self-diagnostic mode are indicated below.
Table 5-3 Maintenance Utility Adjustment Items
Maintenance Utility
1
2
3
4
5
6
7
8
9
10
No.19
No.20
Not operable
No.21
No.21
No.14
No.14
No.3
No.25
No.26
ML3600n
(With a Panel)
Item
Adjustment
Self-diagnosis Menu
Switch scan
test
Motor clutch
test
Execution of
test print
Color drift
correction test
Density
correction test
Indication of
consumable
part counter
Indication of
consumable
part
continuance
counter
Factory/
Shipping mode
switching
Check of Fuse
status
Engine
parameter setup
SWITCH SCAN
MOTOR&CLTCH
TEST
TEST PRINT
REG ADJUST TEST
DENS ADJ TEST
CONSUMABLE
STATUS
PRINTER STATUS
FACTORY MODE
SET
SENSOR SETTING
Checking of inlet sensor and switch
Operation test of motor and clutch
Print of test patterns built in PU
Judgment of good/bad color drift
correction mechanism.
Judgment of good/bad density
correction mechanism.
Indication of consumed state of
consumables
Indication of lifetime consumed state
of consumables
Switching between Factory mode
and Shipping mode
Indication of the status of each fuse
Setup of Enable/Disable of error
detection by various sensors
98
d-Color P116 Service Manual
Y110260-4