7.5
Fuse Checking
If the fuse has blown, the following errors occur. Refer to Table 7-6 and check each fuse on the
main board TB3.
Table 7-6 Errors connected with fuse
Fuse Name
Error Description
Insert Point
F5
F4
F8
F3
F7,F501
F1
F2
Main board
(TB3 PCB)
High Voltage
Board
Hopping error
Papers conveying error
Papers conveying error
ID UP/DOWN error
FAN error
Hopping error
Cover open
Service call 130 to 134 error
Cover open error
POWER LSI error
Paper feed motor, fuser motor 24V
Belt motor,
ID UP/DOWN motor 24V
Solenoid, FAN,
Fuse cutter 24V
Sensor etc. 5V
LED HEAD 5V,3.3V
High voltage 24V
High voltage 5V
Fuse list and location
Maker name Model name
Figure NO
Rated
current
Rated
voltage
F4
LITTEL
0494 001NR 5402212S0102
1
24V
F501
LITTEL
0494 003NR 5402212S0302
3A
5V
F1
WICKMAN
or
LITTEL (*1)
3821200
0663 002
---
2A
50V
F2
WICKMAN
or
LITTEL (*1)
3821125
0663 1.25
---
1.25A
50V
*1 : Fuse F1 and F2 of the high-voltage board should be specified by WICKMAN or LITTEL
5402212S0202
High-
voltage
board
Page 207 Please refer to the figure
of high-voltage power supply board
Page 207 Please refer to the figure
of high-voltage power supply board
Main
board
F7
F3
F5,F8
LITTEL
0494 002NR
Location
2A
3.3V
5V
24V
Page 201 Please refer to figure
of the main board-TB3.
Page 202 Please refer to the fig.
of the main board-TB3.
Page 201 Please refer to the figure
of the main board-TB3.