Service call
154: Error
Service call
155: Error
Service call
160: Error
~
163: Error
Service call
167: Error
Service call
168: Error
Service call
169: Error
Service call
170: Error
171: Error
Service call
172: Error
173: Error
Display
Cause
Details of error
Method
Defective fuse
cutting of belt
unit
Defective fuse
cutting of fuser
Defective toner
sensor detection
It does not occur
during shipping
setting
Thermistor
Slope Error
Compensation
Thermistor Error
Upper Side
Thermistor Error
Thermistor Short
circuit / Open
circuit of the
fuser is detected
Thermistor
Temperature
abnormality (high
or low) of the
fuser is detected
Is the belt unit installed correctly?
Does the error recur?
Is the fuser installed correctly?
Does the error recur?
Is the toner cartridge installed?
Is the lock level of toner set?
Does the error recur?
Does the error recur?
Does the error recur?
Is the error message displayed?
Does the error recur?
Is the error message displayed?
Does the error recur?
Is the error message displayed?
Does the error recur?
Does the error recur?
Does the error recur?
Reinstall the belt unit.
Turn on the power supply again
Replace TB3 board after check cable
connection.
Reinstall the fuser after its
connection connector is cleaned
Turn on the power supply again
Replace TB3 board after check the
cable connection.
Install a toner cartridge.
Turn the lock lever of toner cartridge
to the fixed position.
Remove the right side cover, take
measures to prevent the right side of
the device from being exposed to
ambient light, and confirm that the
toner sensor is lighted during
initialization of the device.
Reconfirm it after replacing the toner
sensor Assy.
Replace the TB3 board.
Turn on the power supply again
Turn on the power supply again after
storage for 30 minutes.
Turn on the power supply again
Turn on the power supply again after
storage for 30 minutes.
Note)
Turn on the power supply again
Turn on the power supply again after
storage for 30 minutes.
Check the cable connection between
the ZAK board and TB3 board and
turn on the power again.
Replace the fuser unit.
Replace the TB3 board.
See Note.
Check the cable connection between
the ZAK board and TB3 board and
turn on the power again.
Replace the fuser unit.
Replace the TB3 board.
No
Yes
Yes
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Table 7-1-2 service call error list (4/6)