Description
Code
nnn
Display on Operator Panel
Ready
LED
Attention
LED
Table 7-1-1 Operator Alarm (5/7)
OPEN TOP COVER
%ERRCODE%:PAPER JAM
REPLACE IMAGE DRUM
%ERRCODE%:%COLOR% DRUM LIFE
REPLACE IMAGE DRUM
%ERRCODE%:%COLOR% DRUM LIFE
REPLACE FUSER
%ERRCODE%:FUSER LIFE
REPLACE BELT
%ERRCODE%:BELT LIFE
REPLACE BELT
%ERRCODE%:BELT LIFE
CHECK TONER CARTRIDGE
%ERRCODE%:%COLOR% IMPROPER
LOCK LEVER POSITION
CHECK IMAGE DRUM
%ERRCODE%:%COLOR% DRUM
MISSING
CHECK FUSER
%ERRCODE%:FUSER MISSING
Off
Off
Off
Off
Off
Off
Off
Off
Off
Blink
Blink
Blink
Blink
Blink
Blink
Blink
Blink
Blink
Jam has occurred in paper path.
Error 381 : Transport
Error 382 : Exit
Error 385 : Around Fuser Unit
Error 389 : Printing Page Lost
The life of the image drum (Alarm)
Error 350 : Y
Error 351 : M
Error 352 : C
Error 353 : K
Warning status takes effect at Cover Open/Close.
The toner empty error is occurred after the image drum
reached its life.
Error 560 : Y
Error 561 : M
Error 562 : C
Error 563 : K
This is displayed until a user exchanges the image drum.
Notifies the fuser has reached its life. This is the error
displayed based on the counter to indicate that the fuser
has reached its life, and printing will stop.
Warning status takes effect at Cover Open/Close.
This error will occur on some user setting mode.
Notifies the transfer belt has reached its life. This is the
error displayed based on the counter to indicate that the
belt has reached its life, and printing will stop.
Warning status takes effect at Cover Open/Close.
Indicates waste toner full. Warning status takes effect
only once at Cover Open/Close, and the error occurs
again when about 500 copies have been printed.
Shows that the toner cartridge lever has not been
locked.
Error 544 : Y
Error 545 : M
Error 546 : C
Error 547 : K
The image drum is not correctly installed.
Error 340 : Y
Error 341 : M
Error 342 : C
The fuser unit is not correctly installed.
Error
381
382
385
389
Error
350
351
352
353
Error
560
561
562
563
Error
354
Error
355
Error
356
Error
544
545
546
547
Error
340
341
342
Error
320
Y110260-4
d-Color P116 Service Manual
141