1.4
Specifications
d-Color P116
Category
Item
Exterior
Dimension
Width of print
Engine
speed(A4)
Fast print time
(A4)
Resolution
CPU
RAM
ROM
Power
Consumption
Operating
Environment
(temperature)
Operating
Environment
(humidity)
Width
Depth
Height
Weight
Width of print
Monochrome
Color
Monochrome
Color
Warm-up time
Low noise mode
LED head
Maximum input resolution
Output resolution
Step
Economic mode
Core
Level 1 cache
Level 2 cache
Clock
Bus width
Resident
Option
Program
Power input
Power saving mode
Idle
Normal operation
Peak
In operation
At stand-by
In storage (1 year max.)
At transport (1 month max.)
At transport (1 month max.)
In operation
At stand-by
In storage
At transport
372mm
478mm
290mm
about 21kg
A4
20ppm
16ppm
10sec
12sec
80sec
Unavailable
600dpi
600
×
1200dpi
True 600
×
1200dpi
True 600
×
600dpi
4 steps 600
×
600dpi
toner saving by lowering light
PowerPC750
32KB
256KB
400MHz
64bit
128MB
256/512MB DIMM
64MB+2MB
100-127VAC (Range 99-140VAC) /
220-240VAC (Range 198-264VAC)
Below 14W
100W(average)
400W
980W
10
°
C-32
°
C,17
°
C-27
°
C
(temperature at full color printing with quality guaranteed)
0
°
C-43
°
C, power off
-10
°
C-43
°
C with drum and toner
-29
°
C-50
°
C with drum and without toner
-29
°
C-50
°
C with drum and toner
20%-80%, 50%-70%
(humidity at fullcolor printing with quality guaranteed)
Max. wet bulb temperature : 25
°
C
10%-90%, Max. wet bulb temperature : 26.8
°
C with power off
10%-90%, Max. wet bulb temperature : 35
°
C
10%-90%, Max. wet bulb temperature : 40
°
C
10
d-Color P116 Service Manual
Y110260-4