22. IMAGE QUALITY PROBLEM
Field Service Ver. 2.0 Jul. 2009
864
TROUBLESHOOTING
22.3.2
Scanner system: white lines, white bands, colored lines and colored bands
in main scan direction
A. Typical faulty images
B. Troubleshooting procedure
A02EF4C508DA
White lines
White bands
Color bands
Color lines
Step
Section
Check item
Result
Action
1
Original
Original is damaged or dirty.
YES
Change original.
2
ADF
Original pad is dirty.
YES
Clean.
3
Original glass
Original glass is dirty.
YES
Wipe the surface clean with a
soft cloth.
4
Machine
o
Scan
Area
o
Image
Position: Top
Edge
(Service Mode)
The adjustment value for [Image
Position: Leading Edge] falls within
the specified range.
NO
Readjust.
5
The problem has been eliminated
through the checks of steps up to 4.
NO
Change exposure unit.
Change CCD unit.
Service Manual Y110571-1