12. SERVICE MODE
Field Service Ver. 2.0 Jul. 2009
466
ADJUSTMENT
/ SETTING
12.4.6
Printer Area-Centering
A. Use
• To vary the print start position in the main scan direction for each paper source.
• The PH Unit has been replaced.
• A paper feed unit has been added.
• The print image deviates in the main scan direction.
B. Procedure
• Width A on the test pattern produced should fall within the following range.
Specifications: 3.0
r
0.5 mm
1.
Call the Service Mode to the screen.
2.
Touch [Machine]
o
[Printer Area]
o
[Centering].
3.
Select the paper source to be adjusted.
4.
Press the Start key to let the machine produce a test print.
5.
Check the dimension of width A on the test print.
6.
If width A falls outside the specified range, change the setting using the [+] / [-] key.
If width A is longer than the specifications, make the setting value smaller than the cur-
rent one.
If width A is shorter than the specifications, make the setting value greater than the cur-
rent one.
7.
Press the Start key to let the machine produce a test print.
8.
Check the dimension of width A on the test print.
9.
If width A is outside the specified range, change the setting again and make a check
again.
10.
If width A falls within the specified range, touch [END].
11.
Following the same procedure, adjust for all other paper sources.
(Use A4 or 8
1
/
2
x 11 plain paper for the bypass.)
A0P0F3C504DA
Width A
Service Manual Y110571-1
Summary of Contents for d-color MF651
Page 1: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Page 24: ...MEASURES TO TAKE IN CASE OF AN ACCIDENT S 22 Blank Page...
Page 27: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Page 1053: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2009 1ST EDITION 1053053 Y110571 1...