10. UTILITY
Field Service Ver. 2.0 Jul. 2009
340
ADJUSTMENT
/ SETTING
(2) Original Stop Position
<Use>
• To manually adjust the original stop position and the read position in each of the ADF
modes.
• When the result is Unable in the [Auto Adj. of Stop Position].
<Procedure>
1.
Place the chart in the document feed tray (with the side having an arrow facing up).
2.
Make a full size copy of the chart.
NOTE
• In the same way place the chart with the blank side facing up in the document feed
tray in the duplex mode and make a copy. Check the difference in the widths of a
between the chart and the second sided surface of the copy sample.
3.
Check that the difference in the widths of B between the chart and the copy sample falls
within the specified range.
Specification B: 0 ± 2.0 mm
Adjustment range: -4.0 mm to +4.0 mm (1 step: 0.1 mm)
4.
Call the Administrator Settings to the screen.
5.
Touch [System Settings]
o
[Expert Adjustment]
o
[ADF Adjustment]
o
[Original Stop
Position].
6.
Look at the copy and adjust [Front] or [Back] with the [+]/[-] key.
If the difference in the widths of B is greater than the specifications, enter the [+] value.
If the difference in the widths of B is smaller than the specifications, enter the [-] value.
7.
Touch [OK].
8.
Make a copy of the chart again and check that the difference in the widths of B falls
within the specified range.
B
A0P0F3C601DA
Service Manual Y110571-1
Summary of Contents for d-color MF651
Page 1: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Page 24: ...MEASURES TO TAKE IN CASE OF AN ACCIDENT S 22 Blank Page...
Page 27: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Page 1053: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2009 1ST EDITION 1053053 Y110571 1...