2KZ/2K0
1-3-31
U066
Adjusting the scanner leading edge registration
Description
Adjusts the scanner leading edge registration of the original scanning.
Purpose
Make the adjustment if there is a regular error between the leading edges of the copy image and
original.
Adjustment
1. Press the start key.
2. Press the system menu key.
3. Place an original and press the start key to make a test copy.
4. Press the system menu key.
5. Select the item to be adjusted.
6. Change the setting value using the cursor left/right keys or numeric keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
Figure 1-3-8
7. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No.
Description
Display
Description
Setting
range
Initial
setting
Change in
value per step
Front
Scanner leading edge registra-
tion
-45 to 45
0
0.091 mm
Rotate
Scanner leading edge registra-
tion (rotate copying)
-45 to 45
0
0.100mm
Original
Scanner leading edge registration (within ± 2.5 mm)
Copy
example 1
Copy
example 2
U066
U403
( P.1-3-73)
U071
( P.1-3-36)
U404
( P.1-3-74)
Y113010-4
Sevice Manual