2KZ/2K0
1-4-30
7402
Developing unit C type mis-
match problem
Absence of the developing
unit C is detected.
Developing unit
connector inserted
incorrectly.
Reinsert the developing unit connector if
necessary.
Different type of
the developing unit
is installed.
Install the correct developing unit.
Defective PWB.
Replace the engine PWB check for correct
operation (see page 1-5-31).
7403
Developing unit M type mis-
match problem
Absence of the developing
unit M is detected.
Developing unit
connector inserted
incorrectly.
Reinsert the developing unit connector if
necessary.
Different type of
the developing unit
is installed.
Install the correct developing unit.
Defective PWB.
Replace the engine PWB check for correct
operation (see page 1-5-31).
7404
Developing unit Y type mis-
match problem
Absence of the developing
unit Y is detected.
Developing unit
connector inserted
incorrectly.
Reinsert the developing unit connector if
necessary.
Different type of
the developing unit
is installed.
Install the correct developing unit.
Defective PWB.
Replace the engine PWB check for correct
operation (see page 1-5-31).
7411
Drum unit K type mismatch
problem
Absence of the drum unit K is
detected.
Drum unit connec-
tor inserted incor-
rectly.
Reinsert the drum unit connector if neces-
sary.
Different type of
the drum unit is
installed.
Install the correct drum unit.
Defective PWB.
Replace the engine PWB check for correct
operation (see page 1-5-31).
7412
Drum unit C type mismatch
problem
Absence of the drum unit C is
detected.
Drum unit connec-
tor inserted incor-
rectly.
Reinsert the drum unit connector if neces-
sary.
Different type of
the drum unit is
installed.
Install the correct drum unit.
Defective PWB.
Replace the engine PWB check for correct
operation (see page 1-5-31).
Code
Contents
Causes
Check procedures/
corrective measures
Service Manual Y113010-4