2KZ/2K0
1-3-84
U464
Setting: [Bias Target/Gamma Target]
1. Select the item to be set.
2. Change the setting value using the +/- or numeric keys.
3. Press the start key. The value is set.
Method: [Calib]
1. Select the item to be set
2. Press the start key. The operation starts.
To stop operation, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No.
Description
Display
Description
Setting
range
Initial set-
ting
1st
Setting of target (Yellow)
10 to 1000
935/400
2nd
Setting of target (Cyan)
10 to 1000
895/200
3rd
Setting of target (Magenta)
10 to 1000
885/200
4th
Setting of target (Black)
10 to 1000
846/130
Display
Description
Regist
Executes the calibration to correct registration.
Gamma
Executes the calibration to quantities of light.
Paper Int
Executes the calibration between paper.
Color Regist
Executes the calibration to color registration.
Service Manual Y113010-4