2KZ/2K0
1-3-83
U464
Setting the ID correction operation
Description
Turns ID correction (calibration) on or off. Also, this determines the duration of calibration and the
timing of calibration during printing. Also, this allows individual settings for calibration operation by
enabling custom settings.
Purpose
To restrict calibration when poor image quality is generated. Also, this allows individual settings
for calibration by enabling custom settings in setting the calibration cycle under the machine
defaults depending on the user preferences.
Method
1. Press the start key.
2. Select the item to be set. The setting screen for the selected item is displayed.
Setting: [Permission]
1. Select the item to be set.
2. Change the setting value using the +/- or numeric keys.
3. Press the start key. The value is set.
Setting: [Time Interval]
1. Select the item to be set.
2. Change the setting value using the +/- or numeric keys.
3. Press the start key. The value is set.
Item No.
Description
Display
Description
Permission
Setting of operation permission
Time Interval
Setting of driving time
Bias Target
Setting of Bias target
Gamma Target
Setting of quantities of light target
Calib
Execution of calibration
Display
Description
Setting
range
Initial set-
ting
Calib
Setting the permission of calibration.
On/Off
On
Paper Int Calib
Setting the permission of calibration
between paper.
On/Off
On
Display
Description
Setting Initial
set-
Paper Int Calib
Setting the driving time of the calibra-
tion between paper.
0 to 100
10
Sleep Out
Setting the execution time of sleeve
return calibration.
0 to 100
20
Y113010-4
Sevice Manual