7. Scanner section (IR section)
Theory of Operation Ver. 1.0 Sep. 2008
20
bizhub C200
Composition/Operation
7.3.4
Original size detection control
A. Detection method
• The reflective original size detection sensors detect the length of an original in the sub scan direction
and the CCD detects the length in the main scan direction.
*1: Size detectable only if the optional original size detection sensor 2 is mounted
Original size
CCD width (mm)
Original size detection
sensor 1
(PS203, Standard)
Original size detection
sensor 2
(PS204, option)
Small size original
0 to 135
OFF
Unset/OFF
5-
1
/
2
x 8-
1
/
2
S
135 to 144
OFF
Unset/OFF
A5S
144 to 163
OFF
Unset/OFF
B5S
163 to 188
OFF
Unset/OFF
16KS *1
188 to 199
OFF
OFF
A4S
199 to 213
OFF
Unset/OFF
8-
1
/
2
x 11S
213 to 226
OFF
Unset/OFF
8-
1
/
2
x 13 *1
ON
OFF
8-
1
/
2
x 14
ON
Unset/ON
B5
226 to 262
OFF
Unset/OFF
B4
ON
Unset/OFF/ON
16K *1
262 to 275
OFF
OFF
8K *1
OFF
ON
8-
1
/
2
x 11
275 to 289
OFF
Unset/OFF
11 x 17
ON
Unset/OFF/ON
A4
289 to 301
OFF
Unset/OFF
A3
ON
Unset/OFF/ON
(non original)
301 or more
OFF
OFF
Original size detection sensor 1
(PS203, Standard)
A02FT2C060AA
Original size detection sensor 2
(PS204, option)
Theory of Operation Y109670-2