20. Image stabilization control
Theory of Operation Ver. 1.0 Sep. 2008
100
bizhub C200
Composition/Operation
20.4 Operation timing
A. Image stabilization at initial operation
B. Image stabilization from the service mode
C. Image stabilization before the start of a print job
Mode
Operation timing
Operation condition
Mode 1
• At main power
ON or sub
power ON
• Front door
opened and
closed
• At the start of
image stabili-
zation after
the last time
when it was
interrupted
• A new transfer belt is detected
• A new IU is detected (Image stabilization sequence is executed only
for a new IU that has been installed)
• Toner empty state is reset.
• In the last image stabilization, the value of IDC registration sensor
detection was out of the specified range.
• The absolute humidity change from the last image stabilization is
greater than a predetermined value.
• The print count reaches 1000 or more after image stabilization was
performed last time.
• During the last image stabilization, a trouble code (P-21/P-22)
appeared.
Mode 2
• The print count is less than 1000 after image stabilization was per-
formed last time.
• Being reacti-
vated from
sleep
• The specified period has passed since the last image stabilization.
Mode 4
• At main power
ON or sub
power ON
• Front door
opened and
closed
• Being reacti-
vated from
sleep
• Temperature change from the last image stabilization is greater than
the specified value.
• Waste toner full detection is reset.
Mode
Operation condition
Mode 1
Init Stabilization
Mode 6
Stabilization only
Mode
Operation condition
Mode 4
During standby, the machine detects the specified amount of change in
inner temperature from the last image stabilization (Only before starting a
color print job.)
Theory of Operation Y109670-2