20. Image stabilization control
99
bizhub C200
Composition/Operation
20.3 Operation sequence
• One of the six modes is selected for image stabilization operation.
*IDC registration sensor detection:
The IDC registration sensor uses the output value calculated in the last IDC registration
sensor adjustment and check that the value measured on the surface of the transfer belt
(background level) is within the specified range. If the measured value is out of the speci-
fied range, mode 1 is used when the next image stabilization is carried out.
* Max. density adjustment control 1: Use default for characteristic tilted value and Vdc
value.
Max. density adjustment control 2: Use previous setting value for characteristic tilted
value and Vdc value.
* LD (laser diode) intensity adjustment control 1: Use default for LD intensity for adjust-
ment pattern.
LD (laser diode) intensity adjustment control 2: Use previous setting value for LD inten-
sity for adjustment pattern.
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
1
IDC registra-
tion sensor
adjustment
IDC registra-
tion sensor
detection
IDC registra-
tion sensor
detection
IDC registra-
tion sensor
detection
IDC registra-
tion sensor
detection
IDC registra-
tion sensor
detection
2
Dmax density
adjustment 1
Dmax density
adjustment 2
Simplified reg-
istration
Simplified reg-
istration
Simplified
gamma cor-
rection
Dmax density
adjustment 2
3
LD light inten-
sity adjust-
ment 1
Simplified reg-
istration
Simplified
gamma cor-
rection
—
—
LD light inten-
sity adjust-
ment 2
4
Registration
Simplified
gamma cor-
rection
—
—
—
Simplified reg-
istration
5
Dmax density
adjustment 2
—
—
—
—
Simplified
gamma cor-
rection
6
LD light inten-
sity adjust-
ment 2
—
—
—
—
—
7
Gamma cor-
rection
—
—
—
—
—
Y109670-2 Theory of Operation