Electricals
WARNING
All electrical work must be done by a qualified electrician, and must meet the
electrical code in your area.
Minimum Circuit Size Required for Model 10014 Planer
Stock Number
Minimum Circuit Size Required
Please ensure the electrical circuit for this machine meets the minimum circuit size requirement.
Minimum circuit size requirement applies to a dedicated circuit which provides power to one 10014
Planer. If more machines are sharing the same circuit, consult a qualified electrician to ensure the
designated circuit is properly sized for safe operation.
If a circuit is available, but not meeting the minimum circuit size requirement listed above, a new circuit
must be installed for this machine.
Grounding
WARNING
Improper grounding can cause electric shock, fire, and equipment damage.
Proper grounding reduces the risk to the operator in the event of electrical malfunction or breakdown.
This machine must be connected to the grounding conductor when available, and all grounding
connections must meet or exceed the electrical code requirements in your area. Furthermore, all
grounds must be verified and must meet or exceed the electrical requirement of the machine. If
grounding is not available. Consider the use of a GFCI protection device as an alternative, if this complies
with the electric code in your area.
Electrical Wiring
This machine is not pre-wired with a plug. A 7-feet long 14 AWG cord is
provided for connecting this machine to a power source. If you plan to
connect the machine directly to the electrical panel (“Hardwiring”).
Please ensure there is a readily accessible electrical disconnect near
the machine. Refer to section “Wiring Diagram” for wiring your
machine to a power source.
If you choose to connect this machine with a plug and a cord, please
use a UL/CSA listed plug. If you need an extension cord to connect to the power outlet, select a durable
cord type with high temperature rating (90C° or above). Both plug and power cord must be sized to
meet the amperage requirement of your machine.
Summary of Contents for 10014
Page 2: ......
Page 10: ...10 Page Oliver Machinery 10014 Planer Identification...
Page 11: ...10014 Planer OLIVERMACHINERY NET 11 Page...
Page 12: ...12 Page Oliver Machinery 10014 Planer...
Page 38: ...38 Page Oliver Machinery 10014 Planer Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6...
Page 44: ...44 Page Oliver Machinery 10014 Planer between the cutterhead and the feed rollers...
Page 51: ...10014 Planer OLIVERMACHINERY NET 51 Page WiringDiagram...
Page 52: ...52 Page Oliver Machinery 10014 Planer PartsList Table Assembly...
Page 53: ...10014 Planer OLIVERMACHINERY NET 53 Page Cabinet Assembly...
Page 54: ...54 Page Oliver Machinery 10014 Planer Motor Mount Assembly...
Page 55: ...10014 Planer OLIVERMACHINERY NET 55 Page Headstock Assembly...
Page 56: ...56 Page Oliver Machinery 10014 Planer Gearbox Assembly and Dust Port Assembly...
Page 62: ...62 Page Oliver Machinery 10014 Planer MaintenanceRecord Date Task Operator...
Page 63: ...10014 Planer OLIVERMACHINERY NET 63 Page Notes...