TOCSIN 700

INSTALLATION

AND

USER INSTRUCTIONS

Summary of Contents for TOCSIN 700

Page 1: ...l Web Site 44 0 161 483 1415 44 0 161 484 2345 sales oliver igd co uk www oliver igd co uk IGD OLIVER 4a Pepper Road Stockport SK7 5BW England Oliver IGD Limited V16 TOCSIN 700 INSTALLATION AND USER I...

Page 2: ...nector The Control Panel is designed to operate within specification for ambient temperature between 5 C and 40 C relative humidity up to 90 non condensing Do not use a Control Panel for protection ap...

Page 3: ...Jog Wheel 3 off Configurable Relay Outputs With Activation Indication Lamps Sounder Flasher Outputs Fault Relay Outputs RS 485 Detector Data Highway Connector Addressable Versions Expansion Connector...

Page 4: ...FAULT relays are normally energised on power up Addressable control panel versions only See Addressable Sensors Section 24V DC SOUNDER O P WARNING LAMP O P Enclosure Ground Enclosure Ground 1 5mmSQ Se...

Page 5: ...GD Tocsin 700 Interface wiring continued Enclosure Ground T103P Pellistor Flammable Gas Detectors 1 5mmSQ See Panel for recommended cable types Typical max cable run 500M 24V DC 4 20 OUT 0V DC 0V DC 4...

Page 6: ...ER IGD Tocsin 700 Interface wiring continued Tocsin 700 to Tocsin 103 2 wire Detector Series Enclosure Ground 4 20mA Toxic And Oxygen Gas Detectors 1 5mmSQ See Panel for recommended cable types Typica...

Page 7: ...as a guide Fit 1 5mm SQ cable for analogue systems Fit 2 5mm SQ cable for addressable systems Use Pirelli LSX type cable for office light commercial un zoned installations Steel Wire Armored or CY cab...

Page 8: ...Suitable for Area Classification 24V SCREEN SCREEN Rx 24V 24V Tx 4 20 B B A A 0V 0V 0V Tocsin 102 Addressable Series Detector Head Red White Yellow Blue Black Local Comms Connector For Palm Connectio...

Page 9: ...o the option to define an input type and scale the incoming 4 20mA signal to match For example pressure temperature distance etc Decide alarm levels for each input and decide rising falling or latchin...

Page 10: ...er programmed description for the sensor is displayed Pressing the jog wheel will accept the indicated alarm If there is more than one alarm tripped then the next alarm is indicated on the display Not...

Page 11: ...programmed in the engineering mode Normal display shows current channel in top left corner Current channels measurement gas reading and measurement units The gas types are stored in EEPROM and can be...

Page 12: ...n the switch is rotated the back light illuminates and the unit stops it s auto scrolling function If no channel is selected or if the button is not rotated within a minute then the unit returns to it...

Page 13: ...s to read zero and the current reading will shift as the zero correction is applied 1 O2 0 VOL CALIBRATING This function allows the user to calibrate a channel As in the case of the zero function sele...

Page 14: ...s channel Factory default is 20 of range Again this uses the current alarm level and is adjusted using the rotation of the switch This menu option sets the alarm type for alarm level 1 Change the set...

Page 15: ...output One additional relay board gives Relays 4 to 11 a second relay board gives relays 12 to 19 Change the relay to be activated in the event of an alarm by rotating the jog wheel Press the jog whe...

Page 16: ...te text part way through a text string hold down the jog wheel until the display flashes Everything past the edit cursor will be erased OLIVER IGD OLIVER IGD This allows the user to edit the descripti...

Page 17: ...enu item Item 4 Address Allows the engineer to select which physical channel the sensor is connected to The channels in the system are arranged logically i e in a four channel system these are labelle...

Page 18: ...l output Note a terminating resistor will be required typically 220 Ohms with a meter in series in order to test the output Item 13 Change Channel As in the Base Menu select to swap to the next sequen...

Page 19: ...0 you will then have to go through the channel set up on each address at the control panel to set Range Units and Gas Type At this time you can also add logical name tags to match the detectors Item 2...

Page 20: ...TION CHANGE CHANNEL ENGINEER EXIT BASE MENU ZERO ZEROING Abort Continue CALIBRATE SET CAL BOTTLE 3000 Abort Continue SET ALARM LEVEL 1 600 SET LEVEL 1 TYPE RISING RISING LATCHING FALLING FALLING LATCH...

Page 21: ...t Test for transmit receive errors Returns to start of basic menu 5 10 25 50 100 200 500 1000 2000 3000 CUSTOM ADDRESS 1 to 65535 SENSOR TYPE T102A T102P T102IR MEASUREMENT LEL PPM VOL CUSTOM GAS TYPE...

Page 22: ...s in the channel output zero routine the 4mA zero output can be set C Analogue output calibration routine Again by measuring the 20mA FSD output and entering this in the channel output calibrate routi...

Page 23: ...420OUT CHANNELS Check the 420OUT CHANNELS function is correctly set this number is set in blocks of 4 channels i e 1 card fitted then set 4 3 420OUT ADDRESS Check the 420OUT ADDRESS function is corre...

Page 24: ...s Rising and Falling Latching Alarms Alarm Set Point Alarm Set Point Alarm O P On Re Set Input On Alarm O P Off Re Set Input Off 5 of Alarm Set Point Alarm Activates Alarm Activates 10 Seconds 10 Seco...

Page 25: ...udio and Visual Alarm Outputs Basic Panel Equipped With 3 Assignable Relay Outputs Dedicated System fault O P TOCSIN 700 D e t e c t o r C o n t r o l P a n e l NOTES Basic Tocsin 700 is supplied conf...

Page 26: ...N G T O C S I N 1 0 2 S E R I E S D E T E C T O R S S E N S O R O P T I O N S A C C E S S O R I E S U S I N G T O C S I N 1 0 2 S E R I E S D E T E C T O R S 5108601 5107901 5112701 5107101 5106801 5...

Page 27: ...data sheet TOCSIN 700 S E N S O R O P T I O N S A C C E S S O R I E S U S I N G T O C S I N 9 0 2 S E R I E S T R A N S M I T T E R S S E N S O R O P T I O N S A C C E S S O R I E S U S I N G T O C S...