min
300
mm
7
8
B
N
A
EN - 16
ENGLISH
Carefully check the characteristics and consistency of the wall in
order to possibly choose wall plugs specific for particular situa
-
tions.
The manufacturer will not be held liable for any underestimates
made in the structural consistency of the anchor prepared by the
installer. Therefore, pay utmost attention to the foregoing opera-
tion that could cause serious injury/damage to people/property if
carried out incorrectly.
•
When installing models equipped with heating pump, if no condensate discharge
was built into the wall (see paragraph 2.4.2), in order to drain the condensate
it will be necessary to drill a hole through the wall in the position shown on the
template.
2.4.2 - Preparing the condensate discharge
•
As regards machines with heat pump, a
condensation drain pipe (fig. 1 - ref. N)
(supplied) to be inserted in the specific
connection (A) (fig. 7).
Remove the cap (B) (fig. 7) before
inserting the condensation drain pipe .
When the max level is reached, a so-
lenoid valve ensures the condensate
will flow out from the internal tray.
• For cold-only machines, connect the
condensate discharge pipe if you
intend running the unit at low outdoor
temperatures (lower than 23°C).
• Since condensate drains by gravity,
there must be a minimum slope of at
least 3% at every point of the discharge
line. Use a rigid or flexible tube having
an inside diameter of at least 16 mm.
• If the line empties into a sewerage system, install a siphon before the point in
which the pipe reaches the main discharge, at least 300 mm below the inlet from
the unit (fig. 8).
Summary of Contents for Unico Air R410A
Page 2: ......
Page 291: ...UNICO AIR ON OFF EL 3 0 0 1 0 2...
Page 292: ...EL 4...
Page 293: ...UNICO AIR ON OFF EL 5 0 3 1 OLIMPIA SPLENDID 2 3 4 5 6 7 8 9...
Page 294: ...EL 6 10 11 12 OLIMPIA SPLENDID 13 14 15 16 17 18 19 20 21...
Page 296: ...EL 8 0 4 12 0 5 OLIMPIA SPLENDID 0 6...
Page 298: ...EL 10 3 2 1 5V 1 2 1 3 a b c 3 d 3...
Page 300: ...min 60mm min 80mm min 60mm min 100mm 2 EL 12 2 3 a 3 b 60 mm 80 mm 2 c 100 mm 80 mm 2 d e...
Page 301: ...UNICO AIR ON OFF 3 EL 13 f 3 g 3 h 3 i 3 l 3 m 3...
Page 302: ...EL 14 2 4 1 m 2 4 1 162 mm UNICO AIR ON OFF UNICOAIR UNICOAIRR32...
Page 303: ...UNICO AIR ON OFF M Y 4 5 6 8mm E E EL 15 4 4 162 mm 5 6...
Page 304: ...min 300mm 7 8 B N A EL 16 2 4 2 2 4 2 1 N A 7 23 C 3 16 mm 300 mm 8...
Page 305: ...UNICO AIR ON OFF 9 10 EL 17 9 J 10 0 C 5 C 2 4 3 H 11 130 mm 11 65 mm...
Page 306: ...162 mm 130 mm G D H H 6mm G G 11 12 13 14 16 15 EL 18 a G D 13 b 2 6 mm 14 15 16 H 11 11 12...
Page 307: ...UNICO AIR ON OFF F F F 17 18 19 20 EL 19 c 17 d 18 e f 19 g h i l 20 m F...
Page 309: ...UNICO AIR ON OFF 24 EL 21 24 2 4 6 1 5mm2 10...
Page 312: ...EL 24 3 10 4 1 2 3 2 led 4 3 3 3 3...
Page 313: ...UNICO AIR ON OFF 31 EL 25 TV 3 3 1 31 a b c 3 3 2 1 5V AAA LR03 31...
Page 314: ...8m 32 EL 26 3 3 3 8 32 3 4...
Page 316: ...30 EL 28 3 5 3 5 1 8 3 5 2 8 I B1 3 5 3 B1 stand by 3 5 4 B4 D3 LED B 30...
Page 317: ...UNICO AIR ON OFF EL 29 3 5 5 40 41 B4 D4 D1 3 5 6 B4 3 5 7 B2 D7 3 5 8 B4 D2...
Page 318: ...30 EL 30 LED B 30 3 5 9 B8 1 B8 3 5 10 B5...
Page 319: ...UNICO AIR ON OFF EL 31 3 5 11 SILENT B3 D6 SILENT B3 B3...
Page 322: ...EL 34 3 5 15 timer timer 11 1 2 1 2 3 5 16 Reset B10 RESET timer B10 3 5 17 3 6...
Page 323: ...UNICO AIR ON OFF 33 EL 35 4 0 OFF 4 1 4 1 1 33 33...
Page 325: ...UNICO AIR ON OFF 30 EL 37 LED A reset H 4 2 a b 4 2 1 2 led 4 2 2 LED A LED B LED C 30...
Page 326: ...6a min 5L 33a EL 38 33a a 6a b 4 3 4 3 1 4 3 4 4 3 3 4 3 2 a b...
Page 328: ...EL 40 TFS5 ON ON ON OFF TFS6 ON ON ON ON ON led OFF led 4 3 4 8 0 8 I...
Page 489: ...278066C...