background image

25

UNICO-HE

Chap. 1

Chap. 2

Chap. 3

GENERAL INFORMATION

1.1

General information

page 26

1.2

Symbols

page 27

1.2.1

Editorial pictograms

page 27

1.2.2

Safety pictograms

page 27

1.3

Technical data

page28

1.3.1

Overall dimensions

page 28

1.3.2

Technical features

page 28

1.3.3

Technical notes

page 28

1.3.4

Proper use

page 28

1.4

List of accessories supplied

page 29

1.4.1

Storage

page 29

1.4.2

Receipt and unpacking

page 29

INSTALLATION

2.1

Instructions for installation

page 30

2.2

Selection of position of the unit

page 30

2.2.1

Choice of best position for installing the air conditioner

page 30

2.2.2

Dimensions and features of site where air conditioner is installed

page 30

2.3

Installation of the unit

page 31

2.3.1

Drilling the wall

page 31

2.3.2

Provision for draining condensate for machines with heat pump

page 33

2.3.3

Installation of air pipes and external gratings

page 33

2.3.4

Power supply connection

page 34

2.3.5

Fitting the unit on bracket

page 35

2.4

Preparation for assembly/installation wall top part

page 35

2.4.1

Introduction

page 35

2.4.2

Removal of front casing

page 35

2.4.3

Preparation of unit

page 36

2.5

Working tests and identification of possible malfunction

page 36

2.5.1

Evacuation of condensation water in case of emergency

page 38

2.6

Periodical maintenance

page 38

USE AND MAINTENANCE (for the user)

3.1

Important Recommendations

page 39

3.2

Names of parts

page 39

3.2.1

List of Units

page 39

3.2.2

Description of signal console

page 39

3.3

Control of Air Conditioner using the remote control unit

page 40

3.3.1

Remote control

page 40

3.3.2

Insertion of batteries

page 40

3.4

Remote control

page 40

3.4.1

Description of the remote control

page 40

3.4.2

Switching on and control of operation

page 41

3.4.3

Switching the unit on and off (button T1)

page 41

3.4.4

Automatic Operation (button T2)

page 41

3.4.5

Cooling function

page 41

3.4.6

Dehumidifier only

page 42

3.4.7

Fan only

page 42

3.4.8

Heating function (only models with heat pump)

page 42

3.4.9

Control of air flow direction

page 42

3.4.10

Control of fan speed

page 43

3.4.11

External air intake

page 43

3.4.12

Night operation

page 44

3.4.13

Setting programs for operation

page 44

3.4.14

Setting of correct time

page 44

3.4.15

Setting of time schedules for 1st and 2nd Operating Program (PROGR. 1 and PROGR. 2)

page 45

3.4.16

Starting and stopping operating programs

page 45

3.4.17

Resetting all functions of remote control

page 46

3.4.18

Control of Air Conditioner if remote control is not available

page 46

3.5

Maintenance

page 46

3.5.1

Cleaning air filter

page 46

3.6

Troubleshooting

page 47

3.6.1

Functional aspects that should not be mistaken for malfunctions

page 47

3.7

Recommendations for energy savings

page 47

3.8

Troubleshooting

page 48

INDEX

Summary of Contents for UNICO 11 HP HE

Page 1: ...eriodical maintenance page 38 USE AND MAINTENANCE for the user 3 1 Important Recommendations page 39 3 2 Names of parts page 39 3 2 1 List of Units page 39 3 2 2 Description of signal console page 39...

Page 2: ...ons and specialization this invalidates the warranty CHAP 3 USE AND MAINTENANCE by user Contains all information and instructions for proper use and programming of the air conditioner as well as instr...

Page 3: ...performing any maintenance on the units The following instructions must be made known to all personnel involved in the machine s transport and installation SYMBOLS The pictograms in the next chapter p...

Page 4: ...HE UNICO 11 HP HE Cooling capacity kW 2 1 2 1 2 45 2 45 Heating capacity kW 1 9 2 035 Capacity absorbed during cooling W 790 790 1100 1100 Absorption during cooling A 3 47 3 47 4 83 4 83 Absorbed powe...

Page 5: ...and is done by expert personnel The units are delivered complete and in perfect condition however we suggest that you perform the following controls of the quality of the shipping service on receipt o...

Page 6: ...eturbulence thatwouldinterferewithcorrect operation of the unit The air conditioner must be installed on a wall that communicates with the outside Caution After determining the best place for installa...

Page 7: ...st tools for drilling large holes in walls are special drills called core borers with very high twisting torque and adjustable rotation speed depending on the diameter of the hole to be drilled To pre...

Page 8: ...se the wall should be inspected carefully to determine the best possible anchorage and type of bolts suitable for particular situations Warning The manufacturer is not liable in case of underestimatio...

Page 9: ...makesure inthiscase thatthewaterexpelled outward does not damage or disturb persons or property During the winter this type of drainage may cause sheets of ice to form After drilling the holes the pl...

Page 10: ...is installed near an outlet you need only plug it in In this case it is important to make sure the outlet to which you are plugged in is effectively grounded and connected to the mains by wiring of ad...

Page 11: ...r conditioner is assembled in the factory ready to be installed low on the wall The air outlet in this case is at the top of the air conditioner with the recycle grating and control panel In order to...

Page 12: ...he casing back on the air conditioner carefully taking care to hold the wires for the step step motor to one side so that they do not interfere with the inner part of the air outlet grating Check that...

Page 13: ...n adjust the temperature reading on the room temperature sensor This correction is important if the air conditioner is installed high on the wall in a room where the warm air tends to stratify upward...

Page 14: ...l will take care of closing the evacuation tube PERIODICAL MAINTENANCE Air conditioners of this type do not require any particular routine maintenance except Cleaning or washing the room air filter wh...

Page 15: ...iminate any ice that could form on the external battery While it is doing this the machine keeps running but does not heat the room This lasts for a brief period of time from 3 to a maximum of 10 minu...

Page 16: ...special collection points provided by the local authorities for this type of waste Replace both batteries at the same time To insert the batteries remove the spring latch cover on the back of the remo...

Page 17: ...ng will not be lost when it is turned off This button serves to switch the air conditioner on or off for brief periods of time In case of prolonged stop of the machine it must be deactivated turning t...

Page 18: ...selection switch until the sun symbol appears on the display First set the desired temperature and fan speed see the specific paragraphs After three minutes maximum time the compressor should start an...

Page 19: ...ct to the effective room temperature As the room temperature nears the setting fan speed is reduced automatically When the unit is operating in dehumidification mode fan speed adjustment is not possib...

Page 20: ...peration is not available for dehumidifying only Night well being mode operation can be halted at any time ideally when you wake up in the morning by pressing button T3 again At this stage the tempera...

Page 21: ...m f Press toggle button T7 to increase or decrease the numerical display of the time when you want program 2 to start Every time you press one end of the toggle button the time setting increases or de...

Page 22: ...nce to a minimum and ensure that they can be performed easily by any user The only operations required are the three types of cleaning illustrated below To ensure effective internal air filtration and...

Page 23: ...ompressor and starting up again This is to safeguard the compressor When heating on versions with the heating pump the machine does not start emitting heat until a few minutes after the compressor sta...

Page 24: ...been an increase in the heating or cooling load for example a door or window has been left open or a device that dissipates a large amount of heat has been installed in the room what to do make sure...

Page 25: ...63 3 2 D nomination des composants page 63 3 2 1 Liste unit s page 63 3 2 2 Description de la console de signalisation page 63 3 3 Gestion de l appareil avec la t l commande page 64 3 3 1 T l command...

Page 26: ...tilisateur Il contient les informations utiles pour comprendre le mode d emploi et la programmation du climatiseur ainsi que les interventions d entretien les plus courantes CHAP 4 ANOMALIES ET LEURS...

Page 27: ...ration d entretien sur les appareils Communiquer ces instructions tout le personnel concern par le transport et l installation de la machine SYMBOLOGIE Les pictogrammes report s au chapitre suivant p...

Page 28: ...rante kW 2 1 2 1 2 45 2 45 Puissance calorifique kW 1 9 2 035 Puissance absorb e en mode de refroidissement W 790 790 1100 1100 Absorption de courant en mode de refroidissement A 3 47 3 47 4 83 4 83...

Page 29: ...L EMBALLAGE L emballage est constitu de mat riau ad quat et effectu par un personnel expert Les unit s sont livr es compl tes et en parfaites conditions suivre cependant les instructions suivantes po...

Page 30: ...lencesquipourraientemp cherlefonctionnement correct de l appareil La position de l installation doit tre choisie sur un mur communiquant avec l ext rieur AVERTISSEMENT Une fois localis e la position c...

Page 31: ...diam tre dans les murs sont des perceuses sp cialis es dot es d une scie tr pan couple de torsion lev et caract ris par une vitesse de rotation r glable selon le diam tre du trou pratiquer Pour viter...

Page 32: ...cution de trous de diam tre de 10 mm De toute fa on il est n cessaire d effectuer un examen attentif des caract ristiques et de la consistance du mur pour le choix ventuel des chevilles appropri es po...

Page 33: ...ne cause ni dommages ni inconv nients aux choses ou aux personnes Pendant l hiver cette eau peut provoquer des formations de plaques de verglas l ext rieur Une fois les trous ex cut s les tuyaux en pl...

Page 34: ...ourant proximit de l appareil il suffit seulement d introduire la fiche M me dans ce cas il est de toute fa on pr f rable de v rifier que la prise laquelle vous vous branchez est dot e d une mise la t...

Page 35: ...sortie de l air se trouve sur le c t sup rieur de l appareil ainsi que la grille de recirculation et le tableau de commandes Pour pr parer le produit tre install dans la partie sup rieure du mur proc...

Page 36: ...it de l appareil Branchez le connecteur du moteur pas pas de la grille Introduisez lentement la coque en prenant soin de placer les c bles du moteur pas pas dans les zones o ils ne g nent pas le c t i...

Page 37: ...temp rature lue par la sonde ambiante Cette correction est importante au cas o le climatiseur serait plac dans la partie haute du mur dans les pi ces o l air chaud stratifie vers le haut pi ces avec...

Page 38: ...RETIEN P RIODIQUE Les climatiseurs de ce type n ont pas besoin d op rations d entretien particuli res part le nettoyage et le lavage du filtre de l air ambiant chaque fois que s allume le voyant de si...

Page 39: ...ormer sur la batterie ext rieure Dans cette situation la machine continue fonctionner mais elle n envoie pas d air chaud dans la pi ce Cette phase peut durer de 3 10 minutes au maximum L appareil ne d...

Page 40: ...remplac es en m me temps Pour introduire les piles il faut ouvrir le couvercle cliquet pr vu cet effet qui se trouve au dos de la t l commande Les piles doivent introduites en respectant scrupuleusem...

Page 41: ...i de m moire si bien que les param trages ne seront pas perdus lorsque l on teindra l installation La touche en question est utilis e pour l activation et la d sactivation de l appareil pendant de cou...

Page 42: ...que s affiche sur l cran l id ogramme qui repr sente le soleil Cette op ration doit tre pr c d e de la s lection de la temp rature d sir e et du choix de la vitesse du ventilateur voir les paragraphe...

Page 43: ...ique au fur et mesure que la temp rature ambiante se rapproche de celle s lectionn e En choisissant le mode d shumidification seulement le contr le de la vitesse n est pas possible vu que l appareil p...

Page 44: ...s La touche confort nocturne n est pas disponible pour le fonctionnement en mode d shumidification seulement La touche confort nocturne peut tre exclue tout moment l id al serait au r veil en appuyant...

Page 45: ...T7 augmentez ou diminuez l indication de l heure laquelle vous souhaitez que l appareil s active avec le 2 programme Chaque fois que vous appuyez sur une extr mit de la touche basculante l indication...

Page 46: ...En effet elles se r duisent aux trois seules op rations de nettoyage d crites ci dessous Pour garantir un filtrage de l air int rieur efficace et un bon fonctionnement de votre climatiseur il est indi...

Page 47: ...u de fa on prot ger le compresseur m me Pendant le fonctionnement en mode chauffage des appareils avec pompe chaleur la sortie de chaleur survient deux minutes environ apr s l activation du compresseu...

Page 48: ...tacles qui g nent le flux d air l int rieur ou l ext rieur donc enlever tout ce qui pourrait g ner les flux d air La charge thermofrigorifique ait augment par exemple qu on ait laiss une porte ouverte...

Page 49: ......

Reviews: