Ethernet MCA 10/100 Adapter v. 1.0, P/N: 710001414
Driver Messages
B.4 OS/2 ODI Driver
The OCE3XODI.SYS OS/2 ODI Driver may generate the following warnings and
error messages:
OCE3XODI-OS/2 Attempt to add MLID protocol ID failed.
There is to little memory in the computer.
OCE3XODI-OS/2 Attempt to allocate memory for Virtual Boards failed.
There is to little memory in the computer.
OCE3XODI-OS/2 LSL support module not installed.
Make sure the Novell LSL.SYS is loaded in CONFIG.SYS
See also the Netware documentation.
OCE3XODI-OS/2 This driver only supports AT or MCA class machines.
The driver has detected that your PC does not conform with the AT or MCA specifications.
Contact your place of purchase.
OCE3XODI-OS/2 This driver only supports 386 processors or higher.
Make sure that the PC is a 386+.
OCE3XODI-OS/2 Error installing interrupt handler.
Try configuring the adapter with another interrupt request level.
OCE3XODI-OS/2 Adapter not found.
Check that the OC-2335 is properly inserted. If this does not solve the problem, check that all software
components are properly installed. Then run the DIAG program.
Contact your place of purchase if the error condition persists.
OCE3XODI-OS/2 Error accessing EEPROM on adapter.
The driver has located the OC-2335 adapter in the system but cannot access its EEPROM. Check that the
adapter is properly inserted. If this does not solve the problem, check that all software components are
properly installed. Then run the DIAG program.
Contact your place of purchase if the error condition persists.
OCE3XODI-OS/2 Adapter failed Built In Self Test.
Contact your place of purchase.
OCE3XODI-OS/2 The Media could not be selected.
The media type selected with DIAG or via keywords cannot be selected. Remove any keywords from the
NET.CFG file and try again. If this does not solve the problem, then run the DIAG program.
OCE3XODI-OS/2 Adapter must be inserted in a 16 bit slot.
Move your adapter to a 16 bit slot.
OCE3XODI-OS/2 Invalid Burned In Address or checksum.
Run the OC-2335 DIAG program.
OCE3XODI-OS/2 I/O port address in NET.CFG is invalid.
Locate and fix the error in NET.CFG See also the NetWare documentation.
OCE3XODI-OS/2 INT parameter from adapter is invalid.
Check that the OC-2335 is properly inserted. Then run the DIAG program.
Contact your place of purchase if the error condition persists.
OCE3XODI-OS/2 The Media could not be AUTO detected.
The media could not be automatically detected. Check that the cable is properly attached.
Then run the DIAG program.
OCE3XODI-OS/2 Cable appears to be disconnected.
Check that the cable is connected. If this does not solve the problem, then run the DIAG program.
OCE3XODI-OS/2 Invalid Node Override, Group Address bit was set now reset.
The NET.CFG file specifies an illegal Node Address
OCE3XODI-OS/2 Invalid Node Override, Local Administrated bit was reset now set.
The NET.CFG file specifies an illegal Node Address
Summary of Contents for 710001414
Page 1: ...Guide to Operations Ethernet MCA 10 100 Adapter OC 2920 1 0...
Page 11: ...4 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Introduction...
Page 13: ...6 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Installation Overview...
Page 17: ...10 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Hardware Installation...
Page 19: ...12 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Windows 95 Express Installation...
Page 61: ...54 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Troubleshooting...
Page 67: ...60 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Contacting Technical Support...
Page 69: ...62 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 System Requirements...
Page 81: ...74 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Driver Messages...