![OLEI LR-1BS2 User Manual Download Page 3](http://html1.mh-extra.com/html/olei/lr-1bs2/lr-1bs2_user-manual_3717283003.webp)
User Manual LR-1BS2
OMEN-1BS2-202202
3
1. About this document
This document summarizes supplementary information on mounting and electrical
installation as well as measured value output format of the LR-1BS2. It is aimed at
sufficiently qualified personnel for the purposes of installation, commissioning and further
data processing. Notes on commissioning, configuration and maintenance can be found in the
LR-1BS2 operating instructions
2. Safety information
Read the notes on mounting and electrical installation before carrying out these tasks.;
Read additionally the LR-1BS2 operating instructions to familiarize yourself with the
device and its functions;
The LR-1BS2 complies with laser class 1.
Only use the device in permissible ambient conditions (e.g. temperature, ground
potential). Any applicable legal regulations or regulations of other authorities will have to
be observed during operation.
Opening the screws of the LiDAR housing will invalidate any warranty claims against
OLEI.
Repairs may only be performed on the LiDAR by trained and authorized OLEI service
personnel
3. Product introduction
The LR-1BS2 is an opto-electronic laser scanner that electro-sensitively scans the
perimeter of its surroundings at a single plane with the aid of laser beams. The LR-1BS2
measures its surroundings using two-dimensional polar coordinates based on its measurement
origin. It can output both point cloud data output and safety signal (I/O port).
Thus LR-1BS2 has been widely applied to industries such as robot obstacle avoidance,
safety monitoring, industrial automation, and intelligent logistics.
4. Installation and operation
4.1.
The LiDAR can be installed in two ways: back-mounted and bottom-mounted.
Back-mounted
There are two M3 screw holes (hole depth is 3mm) at the back of the LiDAR.