2.2.2.
DC power supply
-
Voltage: 21 to 30 V continue. The "-" from continue power supply is linked to
earth (and earth being linked to frame).
-
Maximum power: 240 W
-
Maximum current in cable: 12.5 A
-
Cable: 2 x 2.5 mm² or 2 x 4 mm² depending on length
-
Location of terminal block: see Fig. 8, item D
-
Protection: by two fuses located at the back of the power module (Fig. 8, item E)
.3.
Detectors (Figures 9 and 12)
REMARK
-
The detectors are linked by SHIELDED cables.
-
The utilization of shielded cables is MANDATORY
-
The earth braid of shielded cables must be connected to the earth at one end
only.
CAUTION
Each channel is configured in the factory for a given type of detector (explosive gas, toxic
gas, fire or flame). If two different types of detector are interchanged, this may result in
the destruction of the central unit or of the detector.
2.3.1.
Explosimetric detectors of PONT type
Three connecting wires for a shielded cable.
Resistance of detector / unit cable: 16 ohms maximum per wire, i.e. 32 ohms in loop (1 km for cable
3 x 1.5 mm²).
Connection on MX52 unit: see Fig. 10
Summary of Contents for MX 52
Page 4: ...4 ...
Page 44: ...44 ...
Page 56: ...56 ...
Page 57: ...57 7 7 V VI IE EW WS S S SP PE EC CI IF FI IE ED D I IN N T TH HE E M MA AN NU UA AL L ...
Page 58: ...58 ...
Page 59: ...59 ...
Page 60: ...60 ...
Page 61: ...61 ...
Page 62: ...62 ...
Page 63: ...63 ...
Page 64: ...64 ...
Page 65: ...65 ...
Page 66: ...66 ...
Page 67: ...67 ...
Page 68: ...68 2 ...
Page 69: ...69 ...
Page 70: ...70 ...
Page 71: ...71 ...
Page 72: ...72 ...
Page 73: ...73 ...
Page 74: ...74 ...
Page 75: ...75 ...
Page 76: ...76 ...
Page 77: ...77 ...
Page 78: ...78 ...
Page 79: ...79 ...
Page 80: ...80 ...
Page 81: ...81 ...
Page 82: ...82 ...
Page 83: ...83 ...
Page 84: ...84 ...
Page 85: ...85 ...
Page 86: ...86 ...
Page 92: ...92 ...
Page 93: ...93 ...
Page 94: ...94 ...
Page 95: ......