![OLAER IHV Series Repair Instructions Download Page 1](http://html1.mh-extra.com/html/olaer/ihv-series/ihv-series_repair-instructions_3678353001.webp)
OLAER ( Schweiz ) AG
Bonnstrasse 3
CH - 3186 Düdingen
Telephone 026 / 492 70 00
Telefax 026 / 492 70 70
E-Mail [email protected]
www.olaer.ch
OSP 810
Repair Instructions
Series IHV
23.02.2000 HD
DISMANTLING THE ACCUMULATOR
- Disconnect and close the hydropneumatic accumulator inlet, and discharge the
hydraulic fluid from the accumulator.
- Remove the accumulator from its mounting and lay it horizontally in a vice or other
fixation system. Take care not to damage the accumulator.
- Where necessary, remove the lead seal from the protective cap(s) of the gas inlet
valve. Unscrew the protective cap(s).
- Deflate the bladder using the OLAER tester and pressurizer instrument
(Fig. 1)
.
Operate the tester and pressurizer instrument as described in OSP 746.
- Unscrew the gas inlet valve
(Fig. 2)
.
- Release the gas inlet valve sub-assembly nut, and remove the nameplate
(Fig. 3)
.
- Unscrew the flange or reduction from the hydraulic fluid end.
Dismantle the venting screw, without damaging the gasket ring
(Fig. 4)
.
- Release the ring nut and remove gland ring
(Fig. 5)
.
- Carefully push the hydraulic valve inside the vessel casing
(Fig. 6)
.
- Extract the O-ring.
- Separate the divided anti-extrusion ring/ retention ring from the hydraulic valve
sub-assembly, carefully fold together, and remove from the vessel
(Fig. 7)
.
- Remove the hydraulic valve.
- Extract the bladder through the hydraulic end opening
(Fig. 8)
.
MAINTENANCE AND
SERVICE