DISMANTLING THE ACCUMULATOR

- Disconnect and close the hydropneumatic accumulator inlet, and discharge the

hydraulic fluid from the accumulator.

- Remove the accumulator from its mounting and lay it horizontally in a vice or other

fixation system. Take care not to damage the accumulator.

- Where necessary, remove the lead seal from the protective cap(s) of the gas inlet

valve. Unscrew the protective cap(s).

- Deflate the bladder using the OLAER tester and pressurizer instrument 

(Fig. 1)

.

Operate the tester and pressurizer instrument as described in OSP 746.

- Unscrew the gas inlet valve 

(Fig. 2)

.

- Release the gas inlet valve sub-assembly nut, and remove the nameplate 

(Fig. 3)

.

- Unscrew the flange or reduction from the hydraulic fluid end.

Dismantle the venting screw, without damaging the gasket ring 

(Fig. 4)

.

- Release the ring nut and remove gland ring 

(Fig. 5)

.

- Carefully push the hydraulic valve inside the vessel casing 

(Fig. 6)

.

- Extract the O-ring.
- Separate the divided anti-extrusion ring/ retention ring from the hydraulic valve

sub-assembly, carefully fold together, and remove from the vessel 

(Fig. 7)

.

- Remove the hydraulic valve.
- Extract the bladder through the hydraulic end opening 