3
Planning Pellet Outside Storage
3.1
General
Preparations
1
.
Where and how are the suction lines, power supply for motor (5 x 1,5 mm
2
) and
grounding (min. 6 mm
2
) routed into the house.
2
.
Selection of suitable above- or below-ground cable routing and wall penetration
incl. watertightness must be taken into account.
•
he pipes must be installed above ground in a protective pipe of at least
Ø
DN160
•
or at least
Ø
DN200 must be routed underground.
3
.
Use only bends with 45° to allow easy retraction of the hoses.
For the Flexilo Outdoor outdoor tank, a paved subsoil and a gravel subsoil with a min-
imum height of 10 cm are required. Additional concrete slabs facilitate the installation
of the tank and additionally improve the stability.
NOTICE
Accumulated water must be avoided at all costs!
If underground installation of the suction hoses is selected, the protective tube must
be at least 5 cm above the inner floor edge of the external tank. The protective tube
should protrude to the left or right in the motor area of the tank. The base plate must
be sufficiently recessed in this area
NOTICE
Depending on local conditions, the distance from the house wall should be 10-50 cm.
▶
Observe the country-specific regulations.
CAUTION
The tank must be protected from the weather during installation!
Complete resistance to weathering exists only when the film is mounted on the tank
completely closed.
▶
Only assemble the tank in dry weather conditions.
Required tools
•
Horizontal bar 2 m
•
Measuring tape
•
Pencil
•
Jigsaw
•
Drill, bit inserts, screws
•
Wood drill
Ø
4 mm
•
Hole saws approx.
Ø
51 mm
±
1 mm
and approx.
Ø
30 mm
±
1 mm
6