![Oki ML7065-033 User Manual Download Page 41](http://html1.mh-extra.com/html/oki/ml7065-033/ml7065-033_user-manual_3624632041.webp)
ML7065-033 User’s Manual
Chapter 7 Commands
35
7.3.35 MLME-POLL.confirm
Function: Reports the results of a request to poll the coordinator for data
Command symbol: 0x62
Access: MAC
No. Parameter Type
Value
range
Description
1 Status
U8
SUCCESS,
CHANNEL_ACCESS_FAILURE,
NO_ACK,
NO_DATA,
UNAVAILABLE_KEY,
FAILED_SECURITY_CHECK,
INVALID_PARAMETER
Status indicating the results of a request
for data
7.3.36 MLME-PROTOCOL-ERROR.indication
Function: Gives notice that an error occurred other than errors specified in IEEE802.15.4-2003 (unique
primitive)
Command symbol: 0xFF
Access: MAC
No. Parameter Type Value
range
Description
1
Status
U8
0xF5 or 0xF7
Status value
0xF5: When either a behavior other than those
specified in IEEE802.15.4-2003 is detected or a
shortage of resource is detected
0xF7: When an impossible request in terms of
protocol is received from the host
* This primitive is a unique primitive. When an error other than the errors specified by IEEE802.15.4-2003 occurs in
MAC, this primitive is transmitted to the host system. When the host system receives this indication, issue the
MLME-RESET.request primitive to MAC.