1
2
3
5
4
Con
ven
ient print
functions
Appendix
Index
Checking a
nd
Cha
nging Printer
Settings Using
the Control
Panel
Network
Setup
Matching
Colors
Using Utilit
y
Softw
are
- 313 -
Table of setting items in the device setup screen
Panel Setup
z
Shaded areas are factory-set values.
Item
Details
Near Life Status
Enable
Disable
Sets the panel display control when a near life
warning occurs for the image drum, fuser unit, or
belt.
Near Life LED
Enable
Disable
Sets the alarm lamp ON control when a near life
warning occurs for the toner, image drum, fuser
unit, belt, or waste toner box.
Idle Display
Toner Gauge
Paper Size
Sets the information displayed in the standby
screen.
Panel Brightness During Operating
5
to
31
Adjusts the brightness (backlight luminosity) of the
control panel LCD.
The set brightness is applied during control panel
operations.
Panel Brightness While Power Save
0
to
1
to
31
Adjusts the brightness (backlight luminosity) of the
control panel LCD.
The set brightness is applied after the panel
backlight timer time has eplased from the last
operation.
Panel Backlight Timer
10
to
30
to
300
Adjusts the time (s) from the last operation to
when the panel brightness (during power save) is
applied.
Front Lamp
Mode1
Mode2
Off
Sets the printer front lamp operations.
Mode1:
Lit when in standby mode, flashes slowly during
processing, and flashes rapidly when an error
occurs.
Mode2:
Lit when in standby mode, flashes slowly during
processing, and OFF when an error occurs.
Off:
Normally OFF.
Time Setup
z
Shaded areas are factory-set values.
Item
Details
Date Format
yyyy/mm/dd
mm/dd/yyyy
dd/mm/yyyy
Sets the date display mode.
Time Zone
-12:00
to
+0:00
to
+13:00
Sets the time difference from GMT in 15-minute
units. If the time zone setting is changed, the tome
differences before and after the change is reflected
in the current time.
Memo
z
The factory default is set to +9.00.
Daylight Saving
On
Off
Sets whether to display summertime.
On:
Advances the current time by 1 hour.
Off:
Turns back the current time by 1 hour.
Time Setting
2000/01/01 00 :00
to
2009/01/01 00 :00
to
2091/12/31 23 :59
Sets the time.
Memo
z
The factory default is to set the time.