OKE-2012
oke-2012 user manual V19-9 en.PDF
2
3
1
4
6
5
Low Temp.
Error
High Temp.
Error
92, 1277bungil, Jungangdae-ro, Dongrae-go,
Busan, South Korea
TEL +82 51 5066428 / FAX +82 51 5076430
E-mail :
User Manual
Temperature Controller
☞
Before operating this controller, highly recommended for you
to read this manual carefully without fail.
※
Notandum for safety
‘
Please keep the caution for safety rule to use product correctly
and prevent from accidents or potential threat. The notandum
will give 2 options such as “
Warning” & “Caution
”
Ignoring this symbol could
lead to serious injury or death,
if equipment is handled in
wrong way
!
Waring
Ignoring this symbol could lead
to slightly injury or damage to
the product, if equipment is
handled in wrong way
!
Caution
1. Must set the fail-safe function system when it will install to
control special equipment which will seriously effect a loss of
lives/properties (atomic energy control, medical device,
vehicle,/train/airplane combustion device, recreation/safety
device, etc.).
2. Must set with attaching at panel. Highly concerns an electric
shock.
3.
With power ON, please don’t try to connecting/ repairing/
maintenance. Highly concerns an electric shock
4. Please make sure the terminal number when connect to power.
Highly concerns fire hazard.
5. Only authorized staffs (maker) can reorganize/ reconstruct the
products. Otherwise concerns fire hazard/ electric shock
1. Prohibited to use at outdoor. Otherwise will cause the short
durability of product and concerns a fire hazard.
2. Please use the product within specification ranges. Otherwise will
cause the short durability of product and concerns a fire hazard.
3. Please do not using with over-loaded power at the relay switch
connection. It will cause an error of disconnection/ fire hazard/
relay destroy.
4. Please avoid using the water, organic solvent when it cleaning.
Only use dry towel. It concerns an electric shock & a fire hazard.
5. Please avoid installing at the Inflammable gas/ explosive gas/
direct ray of light/ radiant heat/ vibration/ impact area. It
concerns a fire hazard & explosion.
6. Please keep the product clean & dry without dust/ wire
leftover/etc. it concerns a fire hazard / an operating error
!
Waring
!
Caution
Panel Display description
1.Relay operating indicator
2.Emergency indictor
3.Up button
4.Down button
5.SET mode button
6.FND display (Blink during
Temp. set)
Size & Dimension
Terminal Connection Diagram
Panel attachment Process
Error Code & Reasons
Temp. sensor
short-circuit
Temp. sensor
disconnect
Operation
machine
Relay
Relay
AC 250V 2A