Installation and operation manual

EasyAce

EasyAce

User Manual

Summary of Contents for EasyAce

Page 1: ...M8004 2123EN 10 June 2021 Installation and operation manual EasyAce EasyAce User Manual...

Page 2: ......

Page 3: ...2 4 Home or Away function and Schedules 8 3 Settings and status information 3 1 Status view Overview 13 3 2 Settings menus 13 3 3 Heating 14 3 4 Domestic hot water 17 3 5 Other settings 18 4 Service...

Page 4: ...2 31 M8004 2123EN...

Page 5: ...instructions for how to use your heat pump The instructions for setting up an EasyAce connection are provided as a separate guide Use the wireless touch screen provided with the unit only for operati...

Page 6: ...ter boost 9 Schedules 10 Heat pump status EasyAce Home view ver 2 11 Contextual setting Room temperature Increase or decrease Tap to access the relevant setting 12 Selected heating circuit Tap to open...

Page 7: ...ange the heating circuit displayed in the Home view tap the circuit s number In the figure Circuit 2 is has been selected The Heating circuit window appears Select another circuit and tap OK In the fi...

Page 8: ...room temperature and a negative value will decrease the temperature As changes in room temperature are slow you should change this setting by one or two degrees at a time Wait for one or two days for...

Page 9: ...emperature value in the middle of the house icon The change will apply only to the selected heating circuit 2 Change the setting and tap OK In the figure the target temperature value has been set to 2...

Page 10: ...ck the remaining time tap the boost function icon Here the remaining time is one hour Exit the setting window by tapping Cancel To stop the boost function before this time has elapsed set the time at...

Page 11: ...nit will operate in Normal mode Space heating and domestic water heating operate in Reduced mode Schedules are disabled 1 To change the setting tap the house icon 2 Select either Home or Away and tap...

Page 12: ...omestic hot water In the figure domestic hot water has been selected 2 Press and hold the desired time slot in the schedule In the image Friday at 16 00 has been selected 3 Select the operating mode a...

Page 13: ...igure Normal has been selected Domestic hot water heating will now be boosted between 16 00 and 22 00 6 To save the settings and finish the process tap Save Days with unsaved schedule items are highli...

Page 14: ...was selected 2 Select a new operating mode or select Remove this point In the image below the Remove this point option has been selected 3 Confirm by pressing OK The item scheduled for 22 00 has now b...

Page 15: ...imated performance and power consumption 6 Space heating target for flow temperature 7 Domestic hot water tank measured temperature and target temperature 8 Brine circuit pump speed 3 2 Settings menus...

Page 16: ...he flow water temperature which is determined by the heating curve If a direct connection is used the heating water return temperature condenser in will also be displayed In a direct connection config...

Page 17: ...rature avg An automatically calculated long term outdoor temperature average Max flow temperature The maximum flow temperature when the outdoor temperature matches the Design outdoor temperature setti...

Page 18: ...identical to Circuit 1 settings Heating curve The heating curve indicates the temperature of flow water pumped into the heating circuit at different outdoor temperature points Usually the installatio...

Page 19: ...re for flow water will be 32 C If the system is equipped with an indoor temperature sensor and temperature optimization is enabled this setting will change the room temperature setpoint directly inste...

Page 20: ...nt temperature levels the domestic hot water in the tank can be heated up using both the compressor and the unit s electric immersion heater If domestic hot water temperature remains mostly at or abov...

Page 21: ...current year Hot water An estimate of the energy produced for heating domestic hot water within the current year Electricity An estimate of the compressor s and the electric immersion heater s power...

Page 22: ...he password and tap OK The Service level password is 8520 6 You are now signed in as a service level user Return from the menu by tapping the arrow in the top left corner 4 2 Service settings Device s...

Page 23: ...ace heating Once the delay has elapsed the compressor will stop Increase the delay if you wish to have the compressor run for longer at a time If the delay is greater than 0 flow water temperature can...

Page 24: ...low water temperature from the flow water setpoint Once the measured temperature is above the setpoint the delay will be reset Power decrease delay The delay for switching off power stages The last st...

Page 25: ...eating curve This menu allows you to configure each individual point separately Curve values should be tuned in during the first few heating seasons An example of typical value adjustments If the room...

Page 26: ...he outputs for opening and closing the valve are reversed Heating circuit 1 Q8 closed Q9 open Device settings Service Hot water Hot water Buffer DHW storage tank temperature Compressor Setpoint Target...

Page 27: ...crease the delay if you wish to have the power stages switch off earlier after the flow water temperature exceeds its setpoint If the delay is greater than 0 the heater power stages will remain switch...

Page 28: ...umption and in functions that restrict the heat pump s electrical current Device settings Service Measurements The Measurements view provides a summary of all measurements activation threshold values...

Page 29: ...brine circuit flow or brine circuit return temperature depending on the operating mode Pump not used There is no brine circuit pump connected to the heat pump Outlet temperature The system will contr...

Page 30: ...r space heating Always on The condenser pump will always run at a constant speed at the speed determined by the Speed control setpoint regardless of the Waiting mode action setting Usually the Speed c...

Page 31: ...Manual control The Manual control view allows you to operate the brine pump condenser pump and the system s valves manually Off Manual operation is disabled Manual mode Used Manual operation is enable...

Page 32: ...hows the unit s key operating values from the last 45 days To switch to vertical view tap the full screen button Trend view functions 1 Refresh the view 4 Select the values to display 2 Full screen vi...

Page 33: ...tory can also be accessed from the Main menu Open the main menu from the top left corner or by swiping right from the left edge of the screen Reset alarms from the bottom right corner If the unit does...

Page 34: ...32 31 M8004 2123EN...

Page 35: ......

Page 36: ...Yritt j ntie 6 FI 67100 KOKKOLA FINLAND Niittytie 25 A FI 01300 VANTAA FINLAND Tel 358 0 207 281 868 Fax 358 0 207 281 867 Email info oilon com Contact information of Oilon dealer Date of installation...