background image

1

Ohaus Corporation
29 Hanover Road
Florham Park NJ
07932-0900

Electronic Balances

Mode
Off

Zero

On

g

Scout

 II

Summary of Contents for SCOUT II

Page 1: ...1 Ohaus Corporation 29 Hanover Road Florham Park NJ 07932 0900 Electronic Balances Mode Off Zero On g Scout II ...

Page 2: ...ts radioélectriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matériel brouilleur Appareils Numériques NMB 003 édictée par le ministre des communications Unauthorized changes or modifications to this equipment are not permitted This device corresponds to requirements stipulated in 73 23 EEC and features radio interference suppression in compliance with valid ...

Page 3: ...LINEARITY CALIBRATION 9 ACTIVATING UNITS 10 PARTS COUNTING 10 PRINT MENU 11 SETTING PRINT MENU FUNCTIONS 12 Entering the Print Menu 12 Power On Off 12 Baud Rate 12 Data Bits 13 Parity Bit 13 Stop Bits 13 Auto Print 13 Stable Data Output Only 14 PRINTING 14 RS232 INTERFACE 14 Hardware 14 RS232 Commands 15 Output Formats 15 Error Codes 16 CARE AND MAINTENANCE 16 TROUBLESHOOTING 16 PARTS INFORMATION ...

Page 4: ...Volt battery or with the AC Adapter supplied High capacity model is shown below DESCRIPTION Mode Off Zero On g Scout II ScoutII Balance Calibration Mass Stainless Steel Pan Weigh Below Hook AC Adapter 1 Carefully unpack the balance verify that all items are on hand Save the packing material for transporting the balance 2 Remove the retaining band and cardboard insert from the pan support Calibrati...

Page 5: ...ble environment Do not use the balance in environments with excessive drafts near magnetic fields or equipment that generates magnetic fields rapid temperature changes vibrations or corrosive vapors Power Connect the AC Adapter at the rear of the balance For portable operation install a 9 V battery in the battery compartment as shown in the illustration Pan Installation Place the pan over the pan ...

Page 6: ...ping the balance may display an ERR1 or ERR4 when first turned on This does not mean that the balance is defective We recommend you perform span calibration for an ERR1 indication and linear calibration for ERR4 before you call for service If the balance does not span calibrate try linear calibration Linear calibration requires two masses to be used The 200g 400g and 600g balances are shipped with...

Page 7: ... 3 Place item s to be weighed on the pan and read the weight on the display The stability indicator appears when the reading is stable TARING When weighing items that must be held in a container taring subtracts the container s weight from the total weight on the pan Remember the weight of the container and the material it holds must not exceed the capacity of the balance 1 With an empty container...

Page 8: ...ITS g oz lb oz t dwt pc set each to On or Off PRINT Power On or Off Baud Rate 300 1200 2400 4800 9600 Data Bits 7 or 8 Parity Bit Odd Even or None Stop Bits 1 or 2 Auto Print Continuous On Stability or Off Stable Data Output Only On or Off End LIN Performs linearity calibration END Exit menu and store settings RS232 models only AUTO SHUT OFF ACTIVATION When Auto Shut off is activated the balance w...

Page 9: ... calibration is completed the balance automatically exits the menu and stores any changes you have made SPAN CALIBRATION ScoutII balances are calibrated before shipment however calibration can be affected by changes in location temperature or rough handling Check the bal ance with the calibration mass supplied If calibration is required proceed as follows NOTE 1200g and 6000g balances are not supp...

Page 10: ...isplayed then press Zero On to store settings PARTS COUNTING Parts counting must be turned ON before using this procedure Refer to Activating Units The balance will count parts based on the weight of a reference sample of 5 10 20 or 50 parts For optimum results the parts should be uniform in weight 1 Start with the balance ON in a weighing mode 2 Place a container on the pan and press Zero On to t...

Page 11: ...MENU The Print menu is used to configure and customize the RS232 interface parameters for your requirements on balances equipped with this function The following table shows the sequence in which submenus appear on the Print Menu Factory settings are in bold PRINT MENUTABLE POWER When set ON enables the operation of the RS232 Not recommended for battery operation Baud Rate Specifies baud rate of e...

Page 12: ...ve print menu items See following procedures POWER ON OFF 1 With PoWr displayed press Zero On 2 Press Mode Off to change the displayed setting to On orOFF 3 To accept the displayed setting press Zero On The display returns to PoWr To advance to Baud Rate press Mode Off If you don t want to change any other settings press Mode Off until End is displayed then press Zero On to save settings BAUD RATE...

Page 13: ... press the Mode Off until End is displayed then press Zero On to save setting STOP BITS 1 With StoP displayed press Zero On until either 1 or 2 is displayed 2 Press Mode Off to change the displayed setting to either 1 or 2 3 To accept the displayed setting press Zero On The display returns to StoP To advance to Auto Print press Mode Off If you don t want to change any other settings press the Mode...

Page 14: ...apter is recommended to power the balance when the RS232 interface is used Connecting the balance to a computer enables you to operate the balance from the computer as well as receive data such as displayed weight and weighing mode The following sections describe the hardware and output signal formats provided with the balance Hardware On the rear of the balance a 9 pin subminia ture D connector i...

Page 15: ...ated with a carriage return line feed CRLF TARE COMMAND Field T CR LF Length 1 1 1 RS232 INTERFACE Output Formats Data output can be initiated in one of two ways 1 Using the Auto Print feature 2 Sending a print command P from a computer The output format is illustrated in the RS232 command table which follows RS232 COMMAND TABLE Print current mode nnnnA Set Auto Print Feature to nnnn nnnn 0 turns ...

Page 16: ... to display weight in a particular weighing unit Balance won t store selections made in menu Balance readings unstable Error code is displayed PROBABLE CAUSE 1 Power Adapter not connected 2 Battery is dead Battery is weak 1 Balance out of cali bration 2 Balance was not rezeroed before weighing Incorrect calibration masses being used Weighing unit not activated in menu END selection was not used to...

Page 17: ...Calibration Mass 600g ScoutII 51035 05 ACCESSORIES Part No Calibration Masses 100g 200g ScoutII 51015 05 200g 400g ScoutII 51025 06 300g 600g ScoutII 51035 05 500g 1200g ScoutII 51055 06 1000g 1200g ScoutII 51016 06 2000g 6000g ScoutII 2 required 51026 02 Security Device 76288 01 Hard Shell Carrying Case 77256 01 Impact Printer AS142 Impact Printer Paper 5 pack 78204 01 Cable for AS142 Printer AS0...

Page 18: ...7 1 8 high Pan size W x D in cm 4 10 2 dia 5 x 5 75 12 7x14 6 Dimensions W x H X D in cm 6 75 x 2 4 x 8 25 17 1 x 6 2 x 21 Net weight lb kg 1 5 0 7 1 8 0 8 1 8 0 8 1 8 0 8 1 8 0 8 Shipping weight lb kg 3 2 1 5 3 5 1 6 3 7 1 7 3 7 1 7 3 7 1 7 Item No without RS232 SC2020 SC4010 SC6010 SCA210 SCF0A0 Item No with RS232 SR2020 SR4010 SR6010 SRA210 SRF0A0 CONVERSION FACTORS FOR UNITS OF MASS The follow...

Page 19: ...o point drift g C 0 02 0 2 0 004 0 5 Operating temperature 50 to 104 F 10 to 40 C Operating humidity range 10 to 85 RH Power requirements AC Adapter supplied with balance 100 120 220 or 240 V ac 50 60 Hz or one 9 V battery not included Display in cm LCD 0 7 1 8 high Pan size W x D in cm 4 10 2 dia 5 x 5 75 3 7 6 5 x 5 75 12 7x14 6 12 7x14 6 Dimensions W x H X D in cm 6 75 x 2 4 x 8 25 17 1 x 6 2 x...

Page 20: ...ged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than Ohaus In lieu of a properly returned warranty registration card the warranty period shall begin on the date of shipment to the authorized dealer No other express or implied warranty is given by Ohaus Corporatio...

Page 21: ...20 Ohaus Corporation 29 Hanover Road Florham Park NJ 07932 USA Tel 973 377 9000 Fax 973 593 0359 With offices worldwide www ohaus com P N 80 250 829 Ohaus Corporation 2000 all rights reserved ...

Page 22: ... influence para site est terminée le produit peut être de nouveau utilisé de manière conforme aux prescriptions Dieses Gerät entspricht den Anforderungen nach 73 23 EWG und ist funkentstört entsprechend der geltenden EG Richtlinie 89 336 EWG Hinweis Unter extremen elektromagnetischen Einflüssen z B bei Betreiben eines Funkgerätes in unmittelbarer Nähe des Gerätes kann eine Beeinflussung des Anzeig...

Page 23: ... calibration Pan Installation Place the pan over the pan support as shown in the illustration 7 PAN OPERATION Turning the Balance ON Press ReZero On All segments will appear briefly followed by a soft ware revision number and then Allow 5 minutes warm up time Turning the Balance OFF To turn the balance OFF press and hold Mode Off until the display indicates then release Weighing The balance is shi...

Page 24: ...hen weigh item Use correct masses See error codes note Use Units menu to set desired units ON see menu You must use END to ACTIVATING UNITS AND PARTS COUNTING 1 When the balance displays press ReZero On to display the grams indicator g with its current setting or or 2 To change the displayed setting press Mode Off 3 To accept the displayed setting press ReZero On The display will advance to the ne...

Page 25: ...031 011 R1099 Ohaus Corporation 1999 all rights reserved CONVERSION FACTORS FOR UNITS OF MASS The following conversion table of weights and measures of mass is provided for your work and study when using the balance To Convert from GRAMS TO Multiply by Grains 15 432 36 Carats 5 000 Pennyweights 0 643 014 9 Avoirdupois Drams 0 564 383 4 Avoirdupois Ounces 0 035 273 96 Troy Ounces 0 032 150 75 Troy ...

Reviews: